Where do the Aux feed pumps receive water from for the Steam Generators?
CST
What provides the motive force for Aux Feed ‘A’?
Steam from main steam
What is the mission time for the Aux Feed system?
13 hours and 20 minutes
What is the backup source of water for the class aux feed pumps?
RMWT thru V019
During a loss of off-site power. What can AFN do for us?
It can provide aux feed to the SG’s for 8 hours using the downcomer FW control and isolation valves
When do we get an AFAS?
25.8% SGWL WR 2 out of 4
What happens on an AFAS?
Both class AF pumps start (A and B) Both EDG's start and their auxiliaries S/G blowdown and sampling isolates Flow control and block valves open until 40.8% wide range is acheived
What happens on a SIAS/CSAS?
B AFP starts. N AFP trips if runnings
Both EDG’s start and their auxiliaries
Sias and LOP or LOP. DG autostart.
B Aux feed pump starts. N AFP trips if runnings.
Where do the class aux feed pump room drains go to?
RD system
What provides cooling to the room coolers in the class aux feed pump rooms?
Essential Chill water
What are the class AFP rooms normally cooled by?
Aux Bldg normal AHU
What happens on a high level in a class aux feed pump room?
At approximately 3’ 6” the room dampers will close
What is a delta-p lockout?
When one SG is 185 psig lower then the other one. Feed is stopped to the lower pressure generator.
What is the minimum pump speed to provide adequate oil lubrication of the pump sleeve bearings and pump internals from the shaft driven LO pump?
1000 RPM
Where does AF lube oil cooling water come from?
1st stage of the pump
Where do AF pump room drains go to?
RD system
What cools to the Aux feed pump room coolers inside the pump rooms?
EC
When Aux feed is in its normal standby alignment. What cools the rooms?
Aux Building normal AHU’s
If one of the Aux feed pump rooms has a high level, what happens?
At 3’ 6” the adjoining room dampener will automatically close.
What is a delta-p lockout?
During an AFAS if one of the SG has a 185 psid then the other one. The lower pressure SG will stop receiving feed to prevent feeding a steam leak.
If Aux Feed ‘A’ is running and we lose PKA, what is going to happen?
Lose governor control power, trips on overspeed
Steam supply valves fail as is
Aux feed isolation valves fail as is
What happens to Aux feed ‘N’, if we lose PKA?
Lose control power. Switch to alternate off of ‘A’ class battery charger. Downcomer isolation valves fail open.
Why do we have the temperature indicating strips in the aux fed discharge piping?
We don’t want steam getting back into the discharge piping. It could gas bind the pump and cause water hammer upon flow initiation.