BOOK 1, fire prevention Flashcards Preview

joes fireline problems > BOOK 1, fire prevention > Flashcards

Flashcards in BOOK 1, fire prevention Deck (25):
1

double acting doors shall not be used when occupant load is?

100 or more

2

a standard door should be what dimensions?

3 feet by 6 foot 8 inches

3

if an occupant load of 10 or less exists, you may provide a night latch, dead bolt or security chain. the key or tool should be mounted how high from the floor?

48 inches

4

maximum occupant load a waiting space is?

one person per 7 sq. ft.

5

exit signs should be what dimensions?

6 inches and 3/4 inch letters

6

aisles should be how far from an exit? if equipped with a sprinkler system what can it be extended too?

150 feet
200 feet

7

aisles should not have a dead end greater than?

20 feet

8

how far apart should tables be from one another?

54 inches

9

chairs should be a no more than how many inches from a table?

18 inches

10

xmas tree bases should be stored ?

water or wet sand

11

xmas trees should be field tested for fire resistance, how long in duration?

12 seconds

12

once the flame is pulled away from a field test xmas tree, how long should it take the flame to turn out?

2 seconds

13

how many xmas trees require a special permit, if kept within a building?

10 +

14

how far should lighting be from xmas trees?

6 feet

15

a fire safety tag shall be required for trees measuring?

2 feet or more
1 inch diameter base

16

storage under stairwell is permitted when?

space under stairs is enclosed with a one hour fire resistive construction

17

compressed liquified gases shall not be held longer than ? if in use or on display?

30 days

18

liquified flammable gas cylinders shall not exceed?

5.76 gallons

19

liquified gas shall have a flexible hose of how long? with a bursting pressure of ?

36 inches
1750psig

20

swing doors should swing in exit direction for occupants of ?

50 or more

21

In the event an apt. House has ? Or more dwelling units, or a hotel has ? Or more guest rooms, either the opener, or a responsible resident have charge shall reside on the premises.

16
20

22

Smoke detectors required by Chapter 9 of the LAMC shall be maintained in dependable operating condition and tested every?

6 months

23

An approved automatic or manually activated local fire alarm system shall be provided for all of the following?

Apartment houses 3 or more stories in height
Apartment houses containing 16 or more dwellings units
Hotels, 3 or more stories in height

24

Other than single family dwellings, one unobstructed aisle that leads to each required exit. The minimum width, when not otherwise specified, shall be?

44 inches

25

If a fire alarm system is found to be inoperative during a routine general, night, or pre fire plan inspection, the following procedures should be followed?

Issue a fire /life safety violation F 340C
The alarm system should be restored to full operation immediately
A fire watch shall be maintained if the alarm system cannot be serviced and restored

Decks in joes fireline problems Class (136):