CML Flashcards Preview

ACOM/IFT CAT 1 > CML > Flashcards

Flashcards in CML Deck (32):
1

What does CML stand for?

Command Management LAN

2

What two networks is CML divided into?

NIPRNET (Non-secure Internet Protocol Router Network) & SIPRNET (Secure Internet Protocol Router Network)

3

What is the function of CML?

to provide crew members with IP connectivity, using DNS through the GNOC

4

What does GNOC stand for?

Government Network Operations Center

5

Where are the CML Port Panels located and how many are there?

6 total:
4 in Battlestaff; 1 in Crew Rest; 1 in P20 Bay 3

6

Which CML Port Panel also allows connectivity to the Phased Array Antenna System?

P20 Bay3 / position 17

7

What are the power requirements for the CML Port Panels?

Passive

8

What is the function of the CML Port Panels?

to provide the operator unique keyway polarization between Red & Black ports, allowing connections directly to SIPRNET & NIPRNET

9

Where are the KG-175D (TACLANE-Micros) located and how many are there?

2 total
CML equipment rack, fwd lower lobe

10

What does TACLANE stand for?

Tactical Local Area Network Encryptor

11

What are the power requirements for the KG-175D (TACLANE-Micro)?

+12 VDC from KG-175D Power Supply

12

What is the function of the KG-175D (TACLANE-MIcro)?

to allow secure router traffic for communication

13

Where are the Policy Routers located and how many are there?

2 total
CML equipment rack, fwd lower lobe

14

What are the power requirements for the Policy Routers?

115 VAC 60 Hz from 400/60 Hz Converter

15

What is the function of the Policy Routers?

to perform authentication with the GNOC & set the appropriate routes to allow the KG-175D to establish a Type I encrypted tunnel to the corresponding KG-175D at the GNOC

16

Where are the KG-175D Power Supplies located and how many are there?

2 total
CML equipment rack, fwd lower lobe

17

What are the power requirements for the KG-175D Power Supplies?

115 VAC 60 Hz from 400/60 Hz Converter

18

What is the function of the KG-175D Power Supplies?

to convert the filtered 115 VAC, 60 Hz power from EMI Filter to +12 VDC for the KG-175D

19

Where is the 400/60 Hz Converter located?

E16 equipment rack, fwd lower lobe

20

What are the power requirements for the 400/60 Hz Converter?

115 VAC 400 Hz from PAA & CML c/bs on P67-2

21

What is the function of the 400/60 Hz Converter?

to convert the 115 VAC 400 Hz power to 115 VAC 60 Hz power usable for CML components & PAAS Data Receiver

22

Where is the PAA/CML Power Switch located?

E16 equipment rack, fwd lower lobe

23

What are the power requirements for the PAA/CML Power Switch?

115 VAC 400 Hz from 400/60 Hz Converter and/or the GUPS

24

What does GUPS stand for?

Global Uninterruptible Power Supply

25

What is the function of the PAA/CML Power Switch?

to supply power to the CML components and the PAAS through the various EMI Filters

26

Where are the EMI Filters located and how many are there?

4 total
CML equipment rack, fwd lower lobe

27

What does EMI stand for in EMI Filter?

Electromagnetic Interface

28

What are the power requirements for the EMI Filters?

Passive

29

What is the function of the EMI Filters?

to receive and filter power for the CML;
provide 115 VAC 60 Hz, low-pass filtering to suppress any spurious RF signals

30

Where is the PAA/LAN Power Control Panel located?

P20 Bay 2

31

What are the power requirements for the PAA/LAN Power Control Panel?

28 VDC from PAA/LAN PWR c/b on P20 28 VDC DISTR 1A

32

What is the function of the PAA/LAN Power Control Panel?

to control power to the PAAS, CML, & 60 Hz Converter