CRJ 200 Electric System Flashcards
(19 cards)
Sources of AC Power
2 Engine IDGs
APU GEN
ADG
EXTERNAL
What is the voltage of the AC and DC system?
115v AC
28v DC
Sources of DC Power
5 TRUs
2 Lead/Acid Batteries
28v External Power
Type of power from IDG?
115v, 400hz 3 phase electrical power
What does the FAULT light in the IDG switch light indicate?
High Oil Temps
or
Low Oil Pressure
still supplies power
What are the ways the IDG can disconnect from the engine gearbox?
- pressing IDG DISC switch
- when CSD internal temps raises to a certain temp the IDG will disconnect.
- over torque condition will cause the shearing of the IDG drive shaft.
What monitors the generator system?
GCU
Engine generator will automatically go offline and removed from the system when?
- generator or bus over current
- Over or Under Frequency
- Over or Under Voltage
AC External Power switch lights up green AVAIL it indicates?
AC ground power is plugged in and has: Proper Voltage, Frequency, Polarity.
what are the Volts, HZ, and KVA provided by the ADG?
115v, 400hz, 15 KVA
What are the airspeed limitations for the ADG?
DRY - NONE
WET - Max Continuous - 250 KIAS
up to 330 KIAS - 12 min
331-335 - 4 min
AC Power Priority
- Onside GEN
- APU
- Other-side GEN
- External
AC UTIL BUS LOAD SHED on Ground
- Single GEN
- Flaps >0
- Main Cabin Door Closed
- Galley Service Door
AC UTIL BUS LOAD SHED in Flight
SINGLE GEN
AUTO XFER FAIL
Illuminates for a bus fault or generator over current condition (priority system inhibited).
Associated AC Bus cannot be powered by the APU or the offside generator and cannot be reset in the air.
OFF - press in to disable the priority transfer system. press again to restore normal operation.
ADG AUTOMATIC DEPLOYMENT
- Loss of all AC power
- Last AC Source INTERNAL
- WOW
- Parking Brake - OFF
CHARGER STATUS
Charger not Charging
ESS TIE
Manual ONLY
DO NOT CLOSE ESS TIE if SERVICE TRU is powering DC BUS1/2.
IRREVERSIBLE
AC ESS XFER illuminated when:
the AC ESS BUS is not powered by AC BUS 1.
Press to power the AC ESS BUS from AC BUS 2.
If AC BUS 1 & 2 are not powered the switch illuminates.