Damage Control Flashcards

2
Q

What are two types of portable eductors?

A

S-type and Peri Jet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the P-100 used for?

A

Primary: Firefighting
Secondary: Dewatering

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the primary purpose of eductors?

A

To remove water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What cools the P-100 pump while it is being used?

A

Air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the maximum lift that a P-100 can take suction?

A

20ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What type of fuel does the P-100 pump utilize?

A

JP5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

ESP

A

Electrical Submersible Pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Submersible pumps are not designed for pumping what types of liquids?

A

Gasoline, heavy oils, and hot water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the maximum static head for the ESP

A

70ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When using ESP’s in tandem, which pump do you start first?

A

The bottom one

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

MPE

A

Maximum Permissible Exposure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Who sets MPE and what is it set for default?

A

The CO. 150 RADS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

MOPP

A

Mission Oriented Protective Posture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What are the 5 MOPP levels?

A

Levels 0-4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What type of threads are on a C-2 canister?

A

NATO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What is the purpose of the M-256 A1 kit?

A

Used to detect Nerve, Blood, and Blister agents in vapor form

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the M-291 kit used for?

A

Skin decontamination. Dab onto skin, don’t rub

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What color does M-9 paper turn when an agent is present?

A

Red

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

At what MOPP level is M-9 paper posted?

A

MOPP Level 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is CDU and where is it located?

A

Control Display Unit, located in DC Central

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is RDU and where is it located?

A

Remote Display Unit, located on the Bridge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What is the difference between the CDU and RDU?

A

Bridge doesn’t have controls. Only DC Central has control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What type of system is the IPDS?

A

Fixed(Stationary)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

What does IPDS detect?

A

Chemicals; filters the air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
CCA
Contamination Control Area
27
DS
Decontamination Station
28
Where do you take off your ACPG suit?
Contamination Control Area
29
Where do you take of your coveralls and shower?
Decontamination Station
30
ACPG
Advanced Chemical Protective Garment
31
How long is and ACPG suit good for after it has been taken out of its' original package?
120 days
32
Where are our CCAs?
- Hanger Bay 1 | - Hangar Bay 3
33
Where are our DS?
- 1 FWD by Repair 2 - 2 Mid-ship by Female Chief's head and WEPS male berthing - 1 AFT by RX male berthing
34
HTH
High Test Hypochlorite (Calcium Hypochlorite)
35
What is the purpose of list control?
To keep flight deck level so planes can land
36
How many List Control tanks do we have?
10
37
How many pumps run List Control?
2
38
What type of water is in the List Control tanks?
Potable water
39
Where are the List Control pumps located?
4A Shaft Alley
40
What is the GPM for the List Control pumps?
1800 GPM
41
Who operates the List Control?
DCWS
42
What 2 List Control tanks can hold the most water and why?
113 and 165 because they are on opposite sides of the Island
43
What do we use to determine list?
Clinometer
44
What is the RAM fan used for?
Desmoking
45
What powers the Ram fan?
Firemain
46
What safety precautions must be followed prior to energizing the RAM fan?
Ground it to prevent shock from electro-static build up
47
How many CFM does the RAM fan move?
2000CFM
48
What type of Firemain do we have?
Composite Loop
49
How many fire pumps do we have? How many are electrically driven? How many are steam driven?
23. 19 Electric/ 4 Steam
50
How many Main Drainage Eductors do we have?
13
51
What is the purpose of Main Drainage?
Pump oil waste or water out of the bilges
52
Where is the FWD CHT tank located?
Pump Room 1
53
What type of pump is used for CHT?
Eddie Pump
54
What is H2S and what does it smell like?
Hydrogen Sulfide; smells like rotten eggs
55
How many HICAP AFFF stations do we have?
20
56
How many AFFF mixing stations do we have?
21
57
What is special about AFFF mixing stations 21?
The Bomb Farm
58
What stations are injection pump only?
1,2,11, & 12
59
What is the mixing ration for Firemain and AFFF?
94% Firemain : 6% AFFF
60
What is the GPM for the injection pump?
60GPM
61
What is the GPM for the BPP?
65GPM
62
What does the Pancake Valve do?
Regulates AFFF and Firemain
63
What does SOPV stand for?
Solenoid Operated Pilot Valve
64
What does SOPV do?
Energized the AFFF station
65
How many volts is the SOPV?
440V
66
Where are our reserve tanks located?
HB1- PortsideHB3- Stbdside
67
Where are the reserve pumps located?
AFFF Stations 6 and 13
68
What is the GPM for the reserve pumps?
360 GPM
69
How many Halon Boards do we have?
9
70
What activates the Halon Boad?
5lb CO2 bottle
71
Where are the Halon boards located?
- FWD/AFT EDG - Pump Room 2 - Pump Room 3 - Shaft Alleys
72
What do the lights mean on the Halon Board?
White- Power Available Amber- Halon Activated Red- Halon Discharge Green- Vent Damper
73
What does the 30 sec time delay mean?
Time to evacuate space
74
How many CO2 Fixed Flooding Systems o we have? Where are they located?
4; in the HAZMAT store rooms (3 FWD, 1 AFT)
75
How many SCBA recharge stations do we have? Where are they located?
8: - 1F - 1B - 1A - 2 - 3 - 7F - 7B
76
How do you activate the CO2 Fix Flooding system?
Pull the T-shaped handle until you see red on the cable
77
How many EBACS do we have? Where are they located?
2: 1 Fwd STBD Side 1 Aft next to the Jet Shop
78
If we lose HP air, what do we use to fill the SCBA bottles?
EBACs (Emergency Breathing Air Compressors)
79
Who is the DCA assistant to?
CHENG
80
What is the R&A team?
Rescue and Assistance team; back up to the flying squad
81
What NSTM can you find information about surface ship fire fighting?
NSTM 555
82
Describe the 4 classes of fires
Alpha- Leaves ashes Bravo- HAZMAT, Fuel, Oil Charlie- Electrical Delta- Combustible Metal
83
Name the sides of the fire triangle
Oxygen, Fuel, Heat
84
List the 10 repair lockers
- 1A, 1B, 1F - 2,3,4,5 - 7A, 7B, 7F
85
If DC Central goes down, where is Secondary Central located?
Repair 3
86
What does PKP stand for?
Potassium Bicarbonate
87
What is the effective range of the 18lb PKP bottle?
19ft
88
What is the effective range of the 27lb PKP bottle?
21ft
89
How does PKP extinguish a fire?
Interrupts the chemical reaction
90
What type of fire does PKP primarily put out?
Class Bravo
91
What is the effective range of the CO2 extinguisher?
4-6ft
92
In continuous operation, how long does the 15lb CO2 extinguisher last?
40 Seconds
93
Before you squeeze the lever to release the C02, what must you do?
Ground the cylinder to the deck when discharging to avoid shock from static electricity
94
How does C02 extinguish a fire?
Displaces oxygen
95
What are the best woods for shoring and why?
Douglas Fur and Yellow Pine because they expands when absorbing water
96
What are he 2 size of metal shores?
3-5 FT and 6-11 FT
97
What is the vertical load strength of a 3-5ft metal shore?
3ft- 20,000 lbs5ft- 12,000 lbs
98
What is the vertical load strength of a 6-11ft metal shore?
6ft- 20,000 lbs11ft- 6,000 lbs
99
List the different types of shoring
I- Direct PressureH- No deck anchorageK- Triangular perpendicular
100
What is the strongest type of shoring?
I
101
What is the weakest type of shoring?
H
102
APC
Aqueous Potassium Carbonate
103
What is the APC system used for?
Protection from galley deep-fat and doughnut fryers and their exhaust system
104
How does APC extinguish a fire?
Combines with the hot cooking oil to cut oxygen out
105
Where can you find APC
Galley
106
Who carries the NFTI?
Team Leader
107
NFTI
Naval Firefighting Thermal Imager
108
How many non-rechargeable batteries does the NFTI require and how long do they last?
10 AA alkaline; 3.05 hours
109
What type of rechargeable batteries does the NFTI require and how long do they last?
Lithium Ion; 4.85 hours
110
Who wears a 30 min SCBA bottle?
Investigators, Boundary Men, and Access Men
111
Who wears a 45 min SCBA Bottle?
The Hose Team
112
Who is overall in charge of the hose team?
Team Leader
113
What persent of air do you have left in your SCBA when the Vibra-Alert goes off?
20%-25%
114
Who is the DCO/CHENG?
Captain Select Latterman
115
Who is the DCA?
Lt Cdr Payne
116
Who is the ADCA?
CWO2 Franklin
117
Who is the Firemarshall?
Lt Sales
118
Where is 7F located?
03, near frame 17
119
Where is 7B located?
03, beneath the island
120
Where is 7A located?
03, near 255 frame
121
Where is 2 located?
Near battlemart
122
Where is 4 located?
Near Security
123
Where is 5 located?
Aft Mess Decks
124
Where is 3 located?
XO's Pway
125
Name the kits in the repair locker
``` Shoring Kit Banding Kit Gas Free Kit Banding Kit Pipe Patching Kit ```
126
What else can you find in the repair locker?
NFTI,Stretcher, PECU
127
What are the 3 stages of a fire?
Growth, Flashover, Fully Developed, Decay
128
What manual has procedures for handling casualties?
RPM(Repair Party Manual)
129
Describe the AFFF stations
- 600 gallons each - tanks are 90/10 copper nickel - activated with SOPV (440V) - 4 are injection only