Damage Control Flashcards Preview

Murder Board Questions > Damage Control > Flashcards

Flashcards in Damage Control Deck (110):
1

Who is the DCO?

Chief Engineer/CMDR Crinklaw

2

Who is the DCA?

LCDR Lawry

3

Who is the ADCA?

ENS Aguilar

4

Who is the Ships Fire Marshall?

LT Sales

5

What does DCTT stand for?

Damage Control Training Team

6

Who is the DCTT Leader?

XO

7

Who is the DCTT Coordinator?

Ships Fire Marshall

8

Who are the first responders to a casualty underway?

Flying Squad/At Sea Fire Party

9

What is the job of Rapid Response?

Go straight to the scene and take immediate actions.

10

How many personnel are assigned to Rapid Response?

4 (Fire Marshall, Electrician, 2 Investigators and Boundary men)

11

What is the responsibility of Rescue and Assistance?

Back up Flying Squad and assist other ships in distress

12

What NSTM can you find info about surface ship firefighting?

555

13

If you need to keep a fitting open for am extended amount of time what must you do?

Log it in the Material Conditions Violation section of the Closure Log

14

How long can a fitting remain open for?

No more than 24 hours

15

What do you do if a fitting can not be secured?

Log it in the OOC Log

16

Name one side of the Fire Triangle?

Fuel, Heat, Oxygen

17

Describe an A, B, C, D Fire?

A: White smoke and material leaves ashes. B: Black smoke and fuels and or oils. C: Bluish smoke and Electrical equipment. D: Different colored smoke and combustible metals.

18

What are the 4 stages of a fire?

Growth, Flashover, Fully Developed and Decay

19

How many repair lockers are on board?

10

20

If DC Central goes down, which repair locker assumes command as Secondary DCC?

Repair 3

21

Which repair lockers respond to Main Space Fires?

Repair 4 and 5

22

What do we use to inventory Repair Locker Kits?

AEL (Allowance Equipage List)

23

PKP comes in what to sizes?

18 and 27 pounds

24

What is the effective range of an 18 pound and 27 pound PKP extinguisher?

(19 FT), (21 FT)

25

PKP is a primary extinguishing agent for what class of fire?

Bravo

26

PKP can be used as a last resort on what class of fire?

Charlie

27

Why is PKP used as a last resort on class Charlie fires?

It’s corrosive

28

What is the effective range of a 15 pound CO2 extinguisher?

4-6 feet

29

Under continuous use how long will CO2 last?

40 seconds

30

Before discharging the CO2 extinguisher what should you do?

Ground it

31

Why do we ground the CO2 extinguisher before using it?

To prevent static electric shock

32

What is the distance of portable AFFF extinguishers?

15 feet and decreasing

33

How many gallons of pre-mixed solution is inside the AFFF cylinder?

2 ½ Gallons

34

What are the 2 types of wood we use for Shoring, Plugs and Wedges?

Douglas Fir and Yellow Pine

35

Why do we use Douglas Fir and Yellow Pine?

They expand when they absorb water which makes them stronger

36

What are the 2 sizes of steel shoring?

3-5 feet, 6-11 feet

37

What is the vertical load for a 3-5 foot shore?

3 ft – 20,000 lb, 5 ft -12,000lb

38

What is the vertical load for a 6-11 foot shore?

6 ft – 20,000 lb, 11 ft – 6,000 lb

39

Name one way we can construct shoring?

I Type (direct pressure), H Type (Cross axial), K Type ( triangulation)

40

What is the strongest type of shoring?

I Type

41

What is the weakest type of shoring?

H Type

42

How many types of pipe patches are there?

4

43

What are the 4 types of pipe patches?

Soft, Banding, Jubilee and EWARP

44

What is the only patch that can hold up to a maximum of 100 PSI?

Jubilee

45

What is the max PSI of the other 3 pipe patches?

150 PSI

46

What does EWARP stand for?

Emergency Water Activated Repair Patch

47

What 2 types of portable eductors do we use to dewater?

Peri jet and S-type

48

How many jets are inside the peri jet?

6

49

What size debris can the peri jet pass?

Up to 2 inches

50

Can the S-type pass debris?

NO

51

What powers the Electrical Submersible Pump?

440 Volts

52

How is the ESP cooled?

By what runs through it.

53

What can the ESP not pump?

Fuel, Oil or Hot water

54

How many P-100 pumps do we have on board?

2

55

What are P-100’s cooled by when in use?

Air

56

What type of fuel does the P-100 run off of?

JP-5

57

What is the primary use of a P-100?

Fire Fighting

58

What is the secondary use of a P-100?

Dewatering

59

What powers a ramfan?

Fire Main

60

What safety precaution must be followed before energizing the ramfan?

Ground it

61

How many cubic feet of air will it move?

2000 CFM (Cubic Feet Per Minute)

62

How many ventilation trunks can you put on the suction side of the ramfan?

3

63

How many ventilation trunks can you put on the discharge side of the ramfan?

3

64

What powers the Box Fan?

Electricity

65

How many cubic feet of air will it move?

3200 CFM (Cubic Feet Per Minute)

66

What does NFTI stand for?

Naval Firefighter Thermal Imager

67

Who carries the NFTI?

Team Leader

68

Is the NiMH battery pack rechargeable?

Yes

69

How many and what size batteries are in the NFTI battery pack?

10 AA batteries

70

What does EEBD stand for?

Emergency Escape Breathing Device

71

How long will the OCENCO EEBD last during use?

10 Minutes

72

What are the 2 types of SCBA cylinders used in the Navy?

Fiberglass and Carbon Fiber

73

How can you tell the difference between the 2?

Fiberglass is yellow, Carbon Fiber is grey

74

What 2 sizes of SCBA cylinders are there?

30 minute and 45 minute

75

What is the minimum operating pressure of an SCBA?

4000 PSI

76

What are the 2 types of alarms on the SCBA?

Vibra Alert and Bell alarm

77

The vari nozzle has how many positions?

4

78

What are the positions on a vari nozzle?

Straight stream, Wide V, Narrow V and Flush

79

What GPM is the vari nozzle inside the skin of the ship?

95 GPM

80

How many personnel minimum are required to man a 1 ½” hose?

3

81

How many personnel minimum are required to man a 2 ½” hose?

5

82

When setting boundaries, which one is set first and why?

Top because heat rises

83

If air’s escaping from a sounding tube this could indicate what type of damage?

Flooding

84

If air’s rushing into a sounding tube this could indicate what type of damage?

Fire

85

What is the purpose of list control?

Correct list so we can land planes

86

How many list control tanks do we have?

10

87

How many list control pumps are there?

2

88

What type of water is in the list control tanks?

Potable Water

89

Who operates list control?

DCWS (Damage Control Watch Supervisor)

90

What do we use to determine the list?

Clinometer

91

How many AFFF stations do we have?

20

92

Collectively, where are they located?

2nd deck

93

How much do the AFFF tanks hold?

600 gallons

94

What is the percentage of saltwater to AFFF?

94% Saltwater to 6% AFFF

95

How many reserve tanks do we have?

2

96

How much AFFF do the reserve tanks hold?

3600 Gallons

97

What toxic gas is created when AFFF mixes with salt water?

HS2 ( Hydrogen Sulfide)

98

What is the communication circuit for AFFF?

X-50J

99

What is MPE?

Maximum Permissible Exposure Limit

100

Who sets MPE?

The CO

101

What does MOPP stand for?

Mission Oriented Protective Posture

102

How many MOPP levels are there?

5

103

What does CBR stand for?

Chemical, Biological and Radiological

104

What type of gas mask do we use for CBR attacks?

MCU-2P Gas Mask

105

What type of canister do we use in conjunction with the gas mask?

C-2 Canister

106

What type of threads does the C-2 Canister have?

NATO

107

What does NATO stand for and what does it mean?

North Atlantic Treaty Organization and it can be used with our allies gas masks and vis versa

108

What is the name of the suite we wear in a CBR environment?

JSLIST (Joint Service Lightweight Integrated Suite Technology)

109

What are the 4 types of CBR agents?

Blood, Blister, Nerve and Choking

110

What are some ways we can detect CBR agents?

M-8 paper, M-9 paper, M-256A1 kit, IPDS (Improved Point Detection System), DFU (Dry Filter Unit)