Deck 31 Flashcards
(38 cards)
Add. 1 FAST-PAKAgree or DisagreeThe Fast Pak and riding position SCBA facepiece, regulator, and vibra alert/Pass Alarm are identical.
Disagree- the Fast Pak facepiece/regulator does not have a heads up display indicator, nor does it come equipped with a vibra alert function.
When a distressed member in an IDLH, who is breathing thru his SCBA needs air, what method is most appropriate to provide air? (5, 6.4.4)
High Pressure coupling using the UAC, only by using the Schrader fitting (for use only by SOC via their air cart)
When delivering air using the low pressure hose, you would know that this hose is ______ feet long. (6.1)
20 feet long.
When using the low pressure line, it can be used in any one of 4 methods. Name them. (6.4.1-4)
- Replace the member’s regulator2. Replace the member’s Hansen Fitting3. Replace the member’s facepiece4. Use the Schrader Connection
Agree or DisagreeA Fast-Pak may be used to provide air to non-FDNY members. (7.1)
Agree- The Fast Pak assigned to the FAST unit shall not be used. Additional FAST PAK’s shall be deployed if needed. A Fast Pak may be used if a victim is trapped in an IDLH atmosphere and immediate removal is not possible, or during a Confined Space Operation.
Who will provide a replacement Fast Pak if a company places their OOS? (9.12.2)
The administrative Battalion.
What does the company officer do with the OOS Fast Pak? (9.12.3)
The Company Officer shall forward the OOS Fast Pak to MSU via the Division Messenger.
You are the I.C. at an operation requiring the use of the Fast Truck’s Fast Pak. What must you do? (10.4)
Once a Fast Pak is put into operation, the I.C. shall ensure that a second Fast Pak is readily available at the scene to be used as required.
Add. 2 Facepiece APR’s & Single Scott CBRN Cap 1 CanisterWho shall give the approval to use an APR?a. I.C.b. D.C.c. Command Chiefd. Staff Chiefe. Haz Mat 1
Incident Commander as per sec 1. Sec 4 goes on to say use of an APR should be “after consultation with the Haz Mat group Supervisor, and all the risks have been properly evaluated.”
Where would the use of an APR be prohibited? (4)a. Asbestos incidentb. Bio incident where continuous atmospheric monitoring is necessaryc. Radiological incident where the isotope poses no chemical hazard or the chemical can be filtered by the canisterd. decon ops for a known contaminante. Confined Space Operations
E. Confined Space Ops
The protection of an APR will be dependant upon which of the following factors? (3)a. quality of the facepiece fitb. operating time with APRc. level of activity (increased respiration)d. humidity- high relative humidity shortens the life of organic vapor canisters
All are correct
Scott CBRN Cap 1 Canisters are inspected __________ and/or ____________. (5.2)
At least every 30 days and/or the 1st day of the month.
You are working a day tour in Battalion 1 when you receive a call from a Captain asking if you have filter cartridges and adaptors in stock. You would be correct to tell him ______________. (5.7)
To forward a 23-BS-2 form to the Mask Service Unit.
Where are the Scoot CBRN Cap 1 canisters & adaptors kept on the apparatus? (8.5)
In the infectious control compartment (CFR-D Manual Ch. 3)
If a Scott CBRN Cap 1 Canister is properly stored, it would have a shelf life of _____ years. (8.6)a. 2b. 3c. 5d. 75. 10
D. 7 years
The Scott CBRN has usage time based on the physical state of the contaminant. If it is a liquid exposure it will last _______. If it is exposed to vapors only, dispose of it in _______. 9.5)
Liquid exposure- dispose within 2 hoursVapors Only- dispose of within 8 hours
Battalion vehicles shall carry ___________. Engines, trucks, rescues and squad shall carry ____________. (10.2.3)
Battalions carry 2 adaptors and 4 cartidgesEngines, Ladders, Rescues & Squads carry 6 adaptors and 12 canisters.
Add. 4 Draeger BG-4 Rebreather (EDSCBA)The EDSCBA will provide _____ hours of operating time. (1.3)
Up to 4 hours of breathable air.
For operations in under river tunnels, provided you don’t have to proceed more than 300 feet into the tunnel, what might be another alternative to an EDSCBA? (1.4)
SOC can deploy Supplied Air Respirators fed by hoselines from an Airsource Cart.
Describe the operation of an EDSCBA. How does it work? (2.2)
Exhaled air is scrubbed thru a filter to remove Carbon Dioxide. A small amount of pure oxygen is added to replace the oxygen the wearer consumes. A block of dry ice cools the recycled air.
Under what conditions would you not require the use of the dry ice block in an EDSCBA? (2.3)
When the ambient temperature is below 32 degrees. You need it if the temp is above 32 degrees. But what if the temp IS 32 degrees???
Who may request the response of the Rebreather Unit? (4.1)
The Incident Commander or Rescue Operating Battalion
a Rebreather Response assignment will consist of ………….. (4.2)
Nearest available RRVNearest available RescueNearest available Squad2 additional EDSCBA trained units (Rescue, Squad, HMTU Engine or SSL)Rescue Operating Battalion (or another trained BC if R.O.B. is unavailable)Safety Operating Battalion
If an operation appears the entry will involve a deep penetration and require a large logistical support system, what should you maintain as your Outside Standby Team? (4.4)
2 additional EDSCBA trained companies should be maintained in reserve at the entry point equipped with EDSCBA’s.