Equipment Drains Flashcards

1
Q

What is the purpose of Radwaste?

A

Receive potentially contaminated water wtihin the plant, ‘process’ it in batches, send those batches to above ground sample tanks, and, if aparameters allow, route the sample batches back to 2/3 CSTs for re-use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the purpose of the Equipment Drain System?

A

Receive high quality liquid waste from anticipated leak off points and process it for reuse

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the Waste Collector Tank? Capacity? Location

A

It collects the water from the equipment drain systems, anticipated, clean, leakoff points.
33,000gal
RW Basement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the inputs for the Waste Collector Tank?

A
RBEDT
DWEDS
DWFDS
TBEDS
Waste Demin Off-Standard
Off-Gas Filter Building PDT Pp
Off Gas Drain Pump
Bed Plate Drains
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many pumps are there for the Waste Collector Tank and where are they?

A

there are 2. Located in RW Basement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the Waste Surge Tank? Location? Capacity?

A

Provides a place from which to batch river discharges.
Also large volume for water in excess of Waste Collector Tank Capacity
Located in Tank Farm
77,000gal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How many Waste Surge Tank Pumps are there? Where are they?

A
  1. RW Mezz
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How many Waste Collector Filters are there? Where are they?

What are their flow limits?

A

2 - normally 1 in service.
Located in vaults on RW Mezz
Limited to a max DP of 20psid w/ nominal flow of 200gpm
These remove particulates from the water from WCT or WSgT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the Waste Demin Purpose? LOcation?

Flow Limit?

A

Mixed resin Demin to remove ionic impurities from filter effluent
Located on RW Basement
Limited to max DP of 40psid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the Waste Sample Tanks?
How many are there?
Where are they?
Capacity?

A

Provide a place from which to collect water processed from the Waste Filter, MR and ALPS
Located in Tank Farm
There are 3 - Each 33,000gal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the Resin Cleaner Sludge Tank?
Location?
Capacity?

A

Collects Inputs from Ultrasonic Resin Cleaner
RW Basement
27,500gal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the Waste Filter Sludge Tank?
Location?
Capacity?

A

Collects inputs from WCF backwashes, Fuel Pool Filter Backwash and WCT & WSgT blow down
RW Basement
27,500 gal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the Floor Drain Filter Sludge Tank?
Location?
Capacity?

A

Collects inputs from all filter dome vents, FDCT blowdown, and the A/B Waste Neut Tank Blowdown
RW Basement
27,500gal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the Spent Resin Tank?
Location?
Capacity?

A

Collects inputs from the fuel pool demins, reactor water cleanup demins, condensate demins, max demins, waste demin and mix and hold tank
RW Basement
15,000gal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the RW Sparging system?

A

Air Compressor system used to supply mixing air for sampling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the RW Pump Seal Water System for?

A

Used to seal RW pumps to minimize leakage of highly contaminated fluids out of RW systems

17
Q

What level is it needed to trip the outdoor tank heaters? why?

A

20% level - because will become uncovered and burn up heater

18
Q

What tech spec limits are associated with RW Water?

A

For all ABOVE GROUND TANKS:
No one tank may exceed 0.7Ci and all above ground tanks may not exceed 3Ci TOTAL
MUST get underground w/in 48 hrs if TS limit exceeded to ensure that in the event of an uncontrolled release of the tank’s contents, the resulting limits would not exceed limits

19
Q

WHAT PCIS ISOLATION WILL AFFECT RW?

A

Group II
DWEDS and DWFDS valves isolate
RBEDT Pups and RBFDS Pumps Trip
RBEDT Pump Disch Valves close and recirc valve opens