Flows Flashcards Preview

SkyWest CRJ Upgrade 2019 > Flows > Flashcards

Flashcards in Flows Deck (37):
1

What are the tasks associated with the Safety Check?

MAINTENANCE STATUS
CIRCUIT BREAKERS
EMERGENCY EQUIPMENT
HYDRAULIC PUMP 3A
FFOD CREW OXYGEN MASK
FFOD OBSERVER OXYGEN MASK

2

What are the CP tasks on the originating flow?

Airworthiness acceptance
Gear/ADG pins

3

What are the CP pre-start Tasks?

FUEL QUANTITY
ALTIMETER
FLIGHT INSTRUMENTS
OXYGEN
RADIOS

4

What aural warnings do you hear when you complete the cargo fire test?

“SMOKE”
Triple chime

5

What messages do you see when completing the cargo fire test 1? Test 2?

1: SMOKE CARGO warning message CARGO SQUIB 1 advisory message
2: SMOKE CARGO warning msg CARGO SQUIB 2 advisory msg

6

Which lights are illuminated on the panel when completing cargo test 1? Test 2?

1: NORMAL and STANDBY CARGO SMOKE PUSH
NORMAL BOTTLE ARMED PUSH TO DISCH
2: NORMAL and STANDBY CARGO SMOKE PUSH
STANDBY BOTTLE ARMED PUSH TO DISC

7

What aural warnings are heard when completing the bleed detection test?

Triple Chime
“BLEED AIR DUCT”

8

What messages appear when completing the bleed detection test?

L & R 10th and L & R 14th DUCT, & ANTI ICE DUCT msgs

9

What lights illuminate when completing the Bleed Air Duct test?

L & R 10th and L & R 14th DUCT FAIL warning lights
DUCT FAIL warning light

10

What indications are shown when completing the ICE DETECTOR test?

ICE light illuminated and ICE caution message
OR
ICE advisory message

11

How long do you hold the button for the CVR test?

5 seconds

12

What aural warnings are heard in the MLG overheat test?

“GEAR BAY OVERHEAT”
Triple chime

13

What warning msg is associated with MLG overheat test?

MLG BAY OVHT msg

14

What indications are present when completing the MLG OVHT TEST WARN FAIL?

Single chime and master caution
MLG OVERHEAT FAIL caution msg

15

What emergency equipment needs to be checked in the flight deck?

3 life vests under seats
1 crash axe behind FO
1 escape rope by hatch
2 LED flashlights one on each side
1 PBE behind the CA
1 halon Fire Extinguisher behind FO

16

What conditions must be met to complete the FFOD Stall Test?

HYD 3A on
Flaps 0
Stab Trim 6.0
STALL PTCT ON
Stall : press

17

After the FFOD Stall Test what needs to be turned off?

HYD 3A

18

What test is completed with the EFIS section of the Originating flow?

RA Test

19

What indicates a successful CVR test?

Needle goes in the green arc
Green light illuminates

20

What does the CA say when responding to the O2 part of the Originating checklist?

Checked and actual O2 reading

21

When should the anti-skid switch be moved to armed?

During the originating check flow, when reaching the upper pedestal

22

When are the thrust reversers armed?

During the originating check flow when reaching the thrust lever quadrant

23

When is the TCAS tested?

During the originating check flow, when reaching the lower pedestal

24

What modes must be selected to complete the FFOD Radar Test?

Tilt + 6 degrees
Auto tilt: off
Radar mode selector: off

25

What are the steps of the STAB TRIM TEST?

1. Select : STAB TRIM, CH 1, MACH TRIM
2. Look for STAB TRIM CH2 INOP msg
3. Operate both stab trims in both directions
4. Disconnect FOs stab trim
5. See STAB TRIM and MACH TRIM caution msgs
6. STAB TRIM is inop
7. Select STAB TRIM, CH2 and MACH TRIM
8. See STAB TRIM CH 1 INOP msg
9. Move both switches up/down to clicker activation
10. Press CAs stab trim disconnect
11.see STAB TRIM and MACH TRIM caution msg
12. STAB TRIM is inop

26

What is the last step for the FFOD Stab Trim Test?

Select STAB TRIM CH 1 & 2 and MACH TRIM
Note: caution and status msgs disappear

27

What is the normal position for the compasses?

MAG

28

What needs to be accomplished with the Trim on the originating check?

move the Aileron and rudder trim, and return to center

29

What is the recommended time to start the APU?

10 min prior to departure

30

What do you need to check when turning on the BATT MASTER?

That the charger is greater than 22 volts for the MAIN BATT and the APU BATT

31

What aural warnings are associated with the FFDO Firex Warning Test?

Triple chime
“JET PIPE OVERHEAT”

32

Which lights are illuminated during the FIREX WARN TEST?

L / R ENG FIRE PUSH
APU FIRE PUSH
L / R BOTTLE 1 / 2 ARMED PUSH TO DISCH
APU BOTTLE ARMED PUSH TO DISCH

33

What ED1 msgs are displayed during the FFDO Firex Monitor Test?

APU FIRE
L/R JETPIPE OVERHEAT
L/R ENG FIRE

34

During the FFDO Firex Monitor Test Fail what ED1 indications are shown?

APU FIRE FAIL
R / L JET OVHT FAIL
R / L FIRE FAIL

35

When testing the ENG BTL 1 & 2 and APU BTL on the FFDO Firex monitor test, what indications are you looking for?

ED2 advisory msgs:
L/R ENG SQUIB 1/2
APU SQUIB 1/2

36

Why must HYD 3A be energized during the safety check?

To ensure operation of nose gear doors for walk around inspection
To ensure pressure for parking brake operation

37

What are we checking on the Safety Check when turning on the DC power ? ( BATT MASTER)

Standby lights illuminate
MASTER WARN/MASTER CAUTION lights turn on then extinguish
MAIN BATT >22V APU BATT >22V
* no charge messages??