Aerial reach :
How many sections and made of what?
It will extend to what height at what degrees?
The aerial will go to what degree above horizontal?
- 4 sections; steel
- 107’ above ground at 75°
- 100’ horizontal at 0°
- 77° above horizontal
The tip of the aerial has how many lb. capacity dry at full extension? Wet?
- 750lbs. dry
* 500lbs. wet
Tiller ladder has a flow capacity of ?
Up to 1,000 GPM with Automatic fog nozzle or smooth bore nozzle
It is capable of discharging how many GPM at what PSI in any position in how many mph winds?
- 1000 GPM at 100 PSI
* 50 mph
What is max. flow rating on automatic fog nozzles on end of JFRDs ladder trucks?
2,000 GPM
The aerial has the capability of going how many degrees below horizontal? How?
- 5° below horizontal adjusting the stabilizers
* 15° below horizontal when manipulating stabilizers and the aerial
Nozzle is able to point upward at what degree angle?
30°
Tiller Ladder spec :
Height -
Length -
GVWR -
• 11ft. 1.19in.
• 58ft. 7.5in.
• 73,300lbs.
36.65 tons
The ladder has a safety factor of ?
Based on?
- 2 to 1 (2:1)
* rated load
What does the LEVEL ASSIST switch do?
Controls the stabilizer level assist feature
How many emergency stop buttons are located on the ladder? Where? How do you deactivate the function?
- (3) total emergency stop buttons located on the ladder
- (1) located at each lower control station (1 on each side of all ladders) and (1) located at the turntable control console
- twist the button clockwise to deactivate this function
Where is air horn button located?
On turn table control console
Manual controls for nozzle ?
Hand wheel on top - up/down
Hand wheel on bottom/side - left/right
Older hydraulic system pressure gauge :
This gauge indicates the hydraulic pressure available to operate the aerial. The system standby (bias) pressure is ___.
The max system pressure is ___.
- 350 PSI (+/-10psi)
* 3000 PSI
Aerial controls :
Extend Right Lower
Retract Left Raise
The Pierce 107’ Ascendant Tiller Ladder is equipped with how many special emergency ladder functions?
What are they?
• 4
- OVERRIDE switch
- EMERGENCY HYDRAULIC POWER switch
- AERIAL/STABILIZER EMERGENCY POWER switch, the MANUAL OVERRIDE STABILIZER CONTROLS, and MANUAL OVERRIDE AERIAL CONTROLS
- Electrical failure operations : using the MANUAL OVERRIDE STABILIZER CONTROLS, and MANUAL OVERRIDE AERIAL CONTROLS ONLY
What is the override switch used for?
Used to bypass ALL safety interlocks (except for the emergency stop button)
Where are the manual override stabilizers controls found?
Engineers side of ladder behind a fold down door
The AERIAL/STABILIZER EMERGENCY POWER switch will activate what?
When is it used?
• The electric backup pump
• when the apparatus has a total catastrophic failure
(The aerial master and hydraulic pump are not working and more than likely the truck will not be running)
Where are the manual override aerial controls located?
On the turntable inside the aerial control tower
When’s should the EPU be used?
When the main system hydraulic pump is not operating
The EPU can run continuously for how long? If you need to run the EPU longer than it’s limit, how long should you let it cook down before using again?
- 30 mins.
* 30 mins.
How many batteries does the ladder truck have? How many batteries does the EPU use?
- 6
* 1
If the electronic system has failed and the manual aerial or stabilizer controls are being used, what is the only switch that will be active?
The EPU Switch located at the manual stabilizer controls will be the only one active (emergency hydraulic power switch)