What is the purpose of the Main Steam System?
What is the system designator for the Main Steam System?
SM
What is the purpose of the Steam Generator Flow Restrictor?
What are the major loads supplied by the Main Steam System?
What is the purpose of the Steam Generator Power Operated Relief Valves?
What is the capacity of each Steam Generator PORV, and what are the relief and reset setpoints?
Where are the Steam Generator PORVs located?
2. B and C are located in the inner doghouse
Where can the Steam Generator PORVs be operated from?
What will cause an automatic closure of the Steam Generator PORVs?
A Main Steam isolation signal
What provides the motive force for opening the Steam Generator PORVs in AUTO?
The Instrument Air System(VI) provides air for opening the S/G PORVs with control in AUTO in the Control Room.
What provides the motive force for opening the Steam Generator PORVs in MAN?
In MANUAL control from the Control Room the S/G PORVs are opened from Instrument Air or Nitrogen, whichever is at the higher pressure.
How many Nitrogen Tanks are provided for each Steam Generator PORV?
There are two nitrogen tanks that provide a backup source to operate the S/G PORVs.
What is the basic procedure for operating the Steam Generator PORVs locally in the field?
What are the time critical aspects of the local manual operation of the Steam Generator PORVs?
What is the purpose of the Steam Generator Safety Relief Valves?
The Steam Generator Safety Relief Valves provide overpressure protection for the Steam Generators and the Main Steam System.
How many Steam Generator Safety Relief Valves are there, what is their capacity?
What are the relief setpoints of the Steam Generator Safety Relief Valves?
Relief Sepoints:
(4) 1175psig
(4) 1190psig
(4) 1205psig
(4) 1220psig
(4) 1230psig
Where do the Steam Generator Safety Relief Valves vent to?
The exhaust is vented above the doghouse roof.
What is the purpose of the Steam Generator PORV Block Valve?
The S/G PORV Block Valves are motor operated block valves capable of isolating the PORVs against full open S/G PORV flow, and could be used to limit blowdown should a S/G PORV stick open.
What is the purpose of the Main Steam Isolation Valves?
The Main Steam Isolation Valves stop the uncontrolled steam flow from the Steam Generators in the event of a break in the main steam piping.
How are the Main Steam Isolation Valves positioned, and how do they fail?
2. The MSIVs fail closed on a loss of air or power due to spring pressure.
What is the design closure time of the Main Steam Isolation Valves?
8 seconds
What will cause an automatic closure of the Main Steam Isolation Valves?
A Main Steam Isolation Signal
What is the purpose of the Main Steam Isolation Bypass Valves?