1

All fire hose shall be inspected and service tested in accordance with the applicable requirements of ____ _____, Standard for the Care, Use, and Maintenance of Fire Hose Including Couplings and Nozzles.

NFPA 1962

2

All ground ladders shall be inspected and service tested in accordance with the applicable requirements of ____ ____, Standard of Use, Maintenance, and Service Testing of Fire Department Ground Ladders.

NFPA 1932

3

All fire extinguishers shall be inspected and tested in accordance the applicable requirements of ____ __, Standard for Portable Fire Extinguishers.

NFPA 10

4

No piece of equipment shall be removed from the apparatus without orders or permission of the Shift Commander and compliance with ____ ____ _____ _____ _____ _____. Record must be made in the log book giving reason and authority of the same.

“Section 1.5.3.3, Loaning of City-Owned Equipment”

5

No piece of equipment shall be removed from the apparatus without orders or permission of the Shift Commander and compliance with ____ ____ _____ _____ _____ _____. Record must be made in the log book giving reason and authority of the same.

“Section 1.5.3.3, Loaning of City-Owned Equipment”

6

All accidents or incidents involving any fire department personnel, or equipment wherein the City or the employee might be found at fault will be reported to the City Attorney’s office in writing within __ ____. The ____ _______ will be notified immediately and will make notifications to the____ ____ and the ___ _____ _____.

24 hours

Shift Commander

Fire Chief and the City Safety officer

7

Referring to bunker gear, Cleaning and decontamination solutions shall have a pH range of not less than ____ and not greater than _____.

6.0 pH

10.5 pH

8

The parameters for wind speeds to allow burning is _____ __ ____. The inversion factor must be greater than ____ ____ ____ to allow for open burning. Ozone quality must be above "____" conditions.

Twelve (12) miles per hour

One thousand (1000) feet

Poor

9

Fire hydrant distances for ordinary construction, commercial, and Non combustible and protected by automatic sprinkler system.

400
400
500

10

A fire hydrant shall be located within ____ ___ ___ of all fire department standpipe or sprinkler connections.

fifty (50) feet

11

No more than ___ fire hydrant may be located on any dead-end water main (except when serving only as a utility blow-off). A fire hydrant located on a dead-end water main may not be positioned further than ___ ___ ____ ____ from a looped water supply source. However, up to ____ __ additional hydrants may be added to a dead-end main if the main size is ___ ___ ___ or greater, and the arrangement is approved by the appropriate fire official and the additional hydrants are proven to be hydraulically acceptable for fire department use.

1

three hundred (300) feet

Two (2)

Eight (8) inches

12

When a covered entry is requested, the minimum height shall be no less the ____ __ ____.

Sixteen (16) Feet

13

The minimum clear width of all gates subject to this section shall be _____ __ ____.

fifteen (15) feet