System Pressures, flows, and autostarts Flashcards
(30 cards)
ESW normal psig, flow
90psig
10,000 gpm
ESW autostarts
SI
Load sequence
Low header pressure 40 psig
ESW trips
Load shed
Overload
Overcurrent
Manual
ESW start times
Loadshed w/o si 7 seconds
Loadshed with si or cts 14 seconds
Nesw flow and pressure
80-90 psig
Min flow 2500 gpm
Max flow 4500 gpm
Nesw autostart
Loadshed Load sequence Si Low pressure in auto only U1 65 psig U2 55 psig Manual
Nesw trips
Loadshed
Load conservation w/ cts
Overcurrent overload
Manual
Cow pressure and flow
3000-9000 gpm
100 psig
Ccw pump starts
Si
Loadshed
Low psig on running pp discharge 80#
Ccw trips
Loadshed
Overload
Overcurrent
Condensate flow and pressure
12000 gpm
150
Hotwell autostart
Low discharge pressure on a running pump
U1 pressure 130
U2 pressure 110
Hotwell trips
Overload
Overcurrent
Manual
Condensate booster pump autostart
Low discharge pressure on running pump
325 psig
Condensate booster pp trips
Overload
Overcurrent
manual
Fire protection start sequence
Motor 140 for 2 seconds
East diesel 130 for 15 seconds
West diesel 120 for 25 seconds
Main feed pump trips
Manual Rx trip Si Over speed (107%) IOPS (110%) Thrust bearing wear Lo lube oil pressure 4# 5 seconds Hi hi SG level Low vacuum (20” hg) Lo suction pressure 180# 5 seconds Low trip header pressure 800#
Feedwater isolation
Sg hi hi 67%
Si
Reactor trip with low tave u1 545
u2 554
Tacw flow
8500 gpm u1
8800 gpm u2
Tacw trip
Overload
Overcurrent
Loadshed
Tacw autostart
155 psig u1
145 psig u2
Main Feed pump trips
overspeed manual low vacuum excessive turbine thrust low lube oil pressure reactor trip low suction header pressure SI high high level steam generator
Mainfeed pump auto start
none
feedwater regulating and block valves isolation
reactor trip with low tavg
high high steam generator level
SI
must be reset to reopen valves from the control room