A momentary outage is an electrical outage lasting how long
Two minutes or less
what is a pothead?
A device that provides a transition between underground cable and overhead lines or conductors
primary electric service delivers how many volts to a distribution transformer, which in turn reduces voltage to secondary levels
2,000 to 50,000 V
secondary electric service carries less than how many volts. Most residential and business customers receive electric electricity from secondary distribution loans.
2000 V
A gases flammability limits and _______ represent its physical characteristics with the greatest impact on emergency operations
Vapor density
A one percent drop in the oxygen concentration is equal to how many parts per million
50,000
propane has an expansion ratio of what
270:1
mercaptan - regulation stipulate that a person with a normal sense of smell should be able to detect a concentration in air of what percent of the LEL
20%
Pipeline markers list what three things
commodity transported
The name of the pipeline company
A telephone number where company reps can always be reached
most commercial and all residential appliances use gas at a pressure of what
1/2 to 1/4 psi
LEL operational action levels are as follows: in what percentage range do we investigate the area in full PPE
0 to 10
LEL operational action levels are as follows: in what percentage range do we continue to investigate utilizing SCBA
10 to 25
LEL operational action levels are as follows: above what percentage do we evacuate, secure, utility from the structures, exterior, and perform exterior natural ventilation
25%
During gas, utility emergencies, gas concentrations higher than what percentage of the LEL and CO levels greater than how many parts per million indicating an IDLH
10% of the LEL
1200 ppm of CO
What are five gas utility situations that should queue the IC to request additional resources?
known rescues
Uncontrollable gas leaks
Fire involving pressurized containers
Outside gas leaks involving 2 inch diameter, pipes or larger
Incident involving multiple occupancies
FD personnel must ensure all persons follow OSHA excavation standards dictating no person should enter an unshored trench deeper than how many feet
5
generally, residential levels of CO should not exceed how many parts per million over an eight hour
5 ppm
at CO levels greater than ______ PPM, any persons who enters the structure must wear full turnout gear, including donned SCBA
100 ppm
One transformer normally carries up to how many house
10
what are the four main types of injuries from electrical systems?
Electrocution
Electric shock
Burns
Falls
Many transformers labeled non-PCB contain up to what percent PCB contents
10%
when confronted with an occupied vehicle that is in contact with downed wire wires personnel should stay ______ feet away from the vehicle until the power can be locked out
30 feet
The Virginia state corporation commission approved the ______________________ color codes to Mark underground utilities
American public works associations
The American public Works Association uses which color for electric, cable, conduit, and lighting cable
red