Wyed Lines Flashcards Preview

PUMP CHART > Wyed Lines > Flashcards

Flashcards in Wyed Lines Deck (16)
Loading flashcards...
1
Q

FL for Flowing 165GPM’s

A

2psi

2
Q

FL for Flowing 330GPM’s

A

5psi

3
Q

DP 165GPM’s With 100’ of 3”

A

85psi

4
Q

DP 165GPM’s With 150’ of 3”

A

85psi

5
Q

DP 165GPM’s With 200’ of 3”

A

85psi

6
Q

DP 165GPM’s With 250’ of 3”

A

90psi

7
Q

DP 165GPM’s With 300’ of 3”

A

90psi

8
Q

DP 165GPM’s With 350’ of 3”

A

90psi

9
Q

DP 165GPM’s With 400’ of 3”

A

90psi

10
Q

DP 330GPM’s with 100’ of 3”

A

90psi

11
Q

DP 330GPM’s with 150’ of 3”

A

90psi

12
Q

DP 330GPM’s with 200’ of 3”

A

95psi

13
Q

DP 330GPM’s with 250’ of 3”

A

95psi

14
Q

DP 330GPM’s with 300’ of 3”

A

100psi

15
Q

DP 330GPM’s with 350’ of 3”

A

100psi

16
Q

DP 330GPM’s with 400’ of 3”

A

105psi