Unit 8 Auxiliary Systems Flashcards
Occupancy sensors typically use \_\_\_\_\_\_\_\_\_ for activation. Select one: a. Loud sounds b. Ultraviolet energy c. Ultrasonic energy d. Proximity sensors
c. Ultrasonic energy
Most dimmer switches sold today:
Select one:
a. Divert some current through a variable resistor
b. Can be used with both incandescent or fluorescent lighting
c. Are solid state devices
d. Control lighting levels in response to changing levels of daylight.
c. Are solid state devices
The type of luminaire used in industrial installations and storage areas is the: Select one: a. Open reflector b. Ceiling mount wraparound c. Recessed troffer d. Luminaire
a. Open reflector
One of the three main types of illumination is: Select one: a. Emergency lighting b. Ambient lighting c. General (uniform) lighting d. High intensity lighting
c. General (uniform) lighting
In a "direct" lighting system, all or most of the luminous intensity is: Select one: a. Reflected off the walls b. Directed down toward the work place c. Reflected off the ceiling d. Task lighting
b. Directed down toward the work place
Building codes generally limit the highest pressure permissible in plumbing systems to: Select one: a. 350 kPa b. 490 kPa c. 560 kPa d. 690 kPa
c. 560 kPa
Most municipal water distribution systems operate at pressures between: Select one: a. 350 and 490 kPa b. 250 and 350 kPa c. 490 and 690 kPa d. 590 and 602 kPa
a. 350 and 490 kPa
In a sanitary drainage system, a drain trap should be located within \_\_\_\_\_ of the fixture it serves. Select one: a. 750 mm b. 610 mm c. 1 m d. 50 cm
b. 610 mm
In a circulating domestic hot water system, automatic air vents
Select one:
a. Relieve pressure from the hydro-pneumatic tanks
b. Remove air that is released when water is heated
c. Aerate the water
d. Keep air from entering the water, thus inhibiting corrosion
b. Remove air that is released when water is heated
Some water closets are provided with flush tanks while others are equipped with: Select one: a. Float valves b. Flushometers c. Ball cocks d. Hush tubes
b. Flushometers
The NFPA Life Safety Code requires that emergency lighting be provided for means of exit in:
Select one:
a. Places of assembly of less than 300 people
b. All rental properties
c. Office buildings with occupancies of 300 or more people
d. All educational occupancies
d. All educational occupancies
The building water system that has a storage tank above the highest fixture in the system is called: Select one: a. An up-feed system b. A tankless constant pressure system c. A downfeed system d. A direct pressure system
c. A downfeed system
Which of the following statements about a pressure relief valve in a building hot water system is FALSE?
Select one:
a. The valve may be installed anywhere in the hot water system close to the heater or tank
b. The valve opens when system pressure exceeds the valve set point.
c. The valve closes automatically when the water pressure drops below the valve set point
d. The relief valve may be isolated from the vessel it serves by means of a gate valve, for the purposes of maintenance.
d. The relief valve may be isolated from the vessel it serves by means of a gate valve, for the purposes of maintenance.
Temperature relief devices are effective in protecting domestic hot water systems from:
Select one:
a. Scale build up in the system
b. Flashing of water to steam when faucets are opened
c. Venting off air released from water during heating
d. Inadequate heating of the water
b. Flashing of water to steam when faucets are opened
Ambient lighting can be improved by using both
Select one:
a. direct and indirect lighting
b. natural and ambient lighting
c. fluorescent and incandescent lighting
d. reflective and refractive lighting
a. direct and indirect lighting
With regard to a constant pressure potable water system that uses a pneumatic tank, which of the following statements is FALSE?
Select one:
a. Water from the pump discharges into a pressurized tank
b. Use of this system is limited to larger buildings.
c. A system controller automatically starts a standby pump in the event of pump failure
d. The system has a pressure regulator to maintain a relatively constant pressure above the water level inside the tank
b. Use of this system is limited to larger buildings.