What type of detectors uses for engine fire or overheat detection

A

Continuous loops

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the two types of continuous loop system

A

Semi conductor
Pneumatic pressure loop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the names for pneumatic loops

A

Systron and donner

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How does a pneumatic. Pressure loop work

A

Contains gas sealed within the tube and when the pressure of gas increases at high temps a pressure switch is operated which triggers the alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How’s a semiconductor loop detector work

A

Each tube contains a semiconductor material and the material decreases in electrical resistance with rising temp and an alarms triggered when the resistance is below a certain threshold

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What condition is normal for resistance on a control unit and what condition is normal for resistance in a alarm condition

A

High resistance for normal
Low resistance for alarm condition

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How’s a central warning cancelled

A

By pressing master warning light

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What’s the functions of all fire detection control units

A

Testing
Identify faults
Receive electrical signals from sensors and alarm normal or alarmed position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What type of system do all essential fire warning system have and how many sensors do they have

A

Dual loop
Two sensors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What’s the purpose of two sensors of the dual loop systems

A

To prevent a false warning

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What happens if there’s a failure dual sensor/channel failure in a dual loop system

A

System Won’t operate and must be repaired before next flight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When must an operational check of fire detection test

A

Before each engine or APU start

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What’s semiconductor material is filled within the centre of the semiconductor loop resistor and what does this act as

A

Ceramic sms adds as an endless number of resistors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What characteristic do semiconductor loops work off

A

Negative temp coefficient

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What’s done to prevent the situation a fire which cannot be detected due to an open loop

A

End of loop is connected to the beginning to form a closed loop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What can cause a short circuit of a loop

A

Two parts rubbing together causing damage

17
Q

Why does the short circuit cause a fire warning

A

Because resistance has decreases below 500 ohms

18
Q

What time period must ONE loop report an alarm for before the pilot receives a fault message

A

15 seconds

19
Q

What’s the maximum and minimum bend radius for loops

A

Max- not more than 3.2mm
Min- not less than 25.4mm

20
Q

At what temps does the high pressure gas close the alarm switch and the resistor inside the responder bypassed to cause the control unit to trigger the alarm

A

When the overall heat of airflow is 200 degrees or when a spot on 400

21
Q

What type of fire extinguisher is used for engines

A

Halon 1301

22
Q

What’s a engine fire bottle pressurised with and to what psi

A

Nitrogen and to 600 psi

23
Q

How much do engine fire bottled weight

A

10kg

24
Q

What type of checks would the weight of an extinguisher bottle be checked on

A

C checks

25
Q

Why must the discharge cartridge be handled with care

A

They contain 400g of class c explosives

26
Q

What heated up to cause the cartridge to explode

A

Squib

27
Q

What uses to prevent sparks from static electricity on discharge cartridges

A

Electrostatic protective cap

28
Q

What’s the service life of a discharge cartridge
What’s the max storage life of a discharge cartridge

A

6 years
10 years

29
Q

When does the control light for the fire bottles turn on in the cockpit

A

When pressure decreases by 50% of normal pressure

30
Q

What’s the two methods of checking the function of pressure switch and indication circuit on fire bottles

A

Allen key
Press and hold push button on pressure switch

31
Q

What’s in place to prevent a explosion of the bottle due to overpressurisation

A

Overpressure relief function

32
Q

At what psi does the overpressure relief function operate at

A

1700psi

33
Q

What colour the frangible disc on fire bottles and what would it indicate

A

Red and indicates an overpressure if discharged

34
Q

What colour light comes on after a fire bottle has been discharged

A

Amber

35
Q

What does the yellow disc indicate

A

Bottles discharge and maintenance is necessary

36
Q

What must Be done to the system before a fire can be extinguished

A

Must be isolated

37
Q

How many fire extinguishing shots must engines have

A

2 shot

38
Q

How many shot systems are necessary for APU fire extinguisher systems

A

1 shot

39
Q

What happens after a apu fire warning is activated

A

It’s automatically shut down and after three seconds the circuit automatically fires the bottle