13. A grease interceptor may be used in lieu of an individual fixture trap if the developed length from the fixture outlet to the inlet of the interceptor is not more than: A. 12". B. 24". C. 36". D. 48".
A
D. 48”.( By new code 60” and not more than30” vertically),
1
Q
19. For shower heads, a constant water pressure of 60 pounds per square inch, and a maximum flow under Local Law 29-89 not to exceed: A. 1.6 gallons per minute. B. 1 35 gallons per minute. C. 3 gallons per minute. D. 3.5 gallons per minute.
A
C. 3 gallons per minute.
2 gpm by new code
2
Q
20. Under Local Law 29-89 for urinals and associated flush-vlves, if any, each flush shall not exceed: A. 1.6 gallons per flush. B. 1 gallon per flush. C. 3 gallon per flush. D. 2 gallon per flush.
A
B. 1 gallon per flush.
0.5 gallon by New Code
3
Q
37. The supply lines or fittings for every plumbing fixture shall be so installed as to: A. Flow at even times. B. Prevent stoppages. C. Prevent back-flow. D. Supply 7.5 gallons per minute.
A
C. Prevent back-flow.
4
Q
- Frost-proof water closets used for temporary installations only will be:
A. Prohibited.
B. Permitted by the Commissioner.
C. Permitted.
D. Allowed if the fire Commissioner permits.
A
B. Permitted by the Commissioner.