Engines Flashcards
Max EGT 319/320 TOGA and Time Limit
635*C (5 min Lim 2 Eng, 10 min OEI)
Max EGT MCT 319/320/321
610* C
Max EGT Eng Start 319/320/321
635* C
Max EGT TOGA 321 and Time Limit
650* C (5min Lim 2 Eng, 10 min OEI)
Max EGT TOGA 320 NEO and Time Limit
1083*C (5 min 2 Eng, 10 min OEI)
Max EGT MCT 320 NEO
1043* C
Max EGT Eng Start 320 NEO
1083* C
Min Eng Oil temp for Start
-40* C
Minimum Oil Temp to exceed Idle
-10*C
Minimum Oil Pressure NEO
65 PSI
How many start attempts are considered 1 start cycle (non NEO)
1
For ground starts, how long must you pause between each start cycle? (Non NEO)
15 seconds
(NON NEO) how long of a cooling period is required after ___ failed cycles or ___ minutes of continuous crank?
3 Answers
30 min cooling period
After 3 failed cycles or
5 minutes of continuous crank
(Non NEO) max cycle time for a manual eng start.
2 minutes
(Non NEO) Max cycle time for a Crank
5 min