Ch 2 - Definitions Flashcards

1
Q

Fill in the blank

When applied to a fixture, connection, appliance, or equipment, _____ means having access to, but which first may require the removal of an access panel, door, or similar obstruction.

A

Accessible

Where applied to a fixture, connection, appliance, or equipment, “accessible” means having access thereto, but which first may require the removal of an access panel, door, or similar obstruction.

2024 UPC- 203.0 Definitions - Accessible.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Fill in the blank

_____ means having direct access without the necessity of removing any panel, door, or similar obstruction?

A

Readily accessible

Having a direct access without the necessity of removing a panel, door, or similar obstruction.

2024 UPC- 203.0 Definitions - Accessible, Readily.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is defined as an assembly of listed semi-rigid or flexible tubing and fittings to carry fuel between a fuel piping outlet and a fuel-burning appliance?

A

Appliance Fuel Connector

An assembly of listed semi-rigid or flexible tubing and fittings to carry fuel between a fuel piping outlet and a fuel-burning appliance

2024 UPC- 203.0 Definitions - Appliance Fuel Connector.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Fill in the blank

A room equipped with a shower, bathtub or combination of these is a _____.

A

Bathroom

A room equipped with a shower, bathtub, or combination bath/shower.

2024 UPC- 204.0 Definitions - Bathroom.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fill in the blank

A vent connecting one or more individual vents with a vent stack or a stack vent is a _____.

A

Branch Vent

A vent connecting one or more individual vents with a vent stack or stack vent.

2024 UPC- 204.0 Definitions - Branch Vent.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Fill in the blank

The building drain shall extend _____ feet outside of the building walls before connecting to the sewer?

A

2 feet

That part of the lowest piping of a drainage system that receives the discharge from soil, waste, and other drainage pipes inside the walls of the building and conveys it to the building sewer beginning 2 feet (610 mm) outside the building wall.

2024 UPC- 204.0 Definitions - Building Drain.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Fill in the blank

A _____ is the principle artery of the venting system to which vent branches may be connected.

A

Main Vent

The principal artery of the venting system to which vent branches may be connected.

2024 UPC- 215.0 Definitions - Main Vent.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Fill in the blank

This code refers to water that meets the requirements of the Authority Having Jurisdiction to be satisfactory for culinary, domestic, and drinking purposes as _____.

A

Potable water

Water that is satisfactory for drinking, culinary, and domestic purposes and that meets the requirements of the Health Authority Having Jurisdiction.

2024 UPC- 218.0 Definitions - Potable Water.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Fill in the blank

_____ is the force exerted by a homogeneous liquid or gas, per unit of area, on the wall of a container.

A

Pressure

The normal force exerted by a homogenous liquid or gas, per unit of area, on the wall of the container.

2024 UPC- 218.0 Definitions - Pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Fill in the blank

A _____ is an appliance for supplying hot water for domestic or commercial purposes.

A

Water Heater

An appliance designed primarily to supply hot water for domestic or commercial purposes and equipped with automatic controls limiting water temperature to a maximum of 210蚌 (99蚓).

2024 UPC- 225.0 Definitions - Water Heater or Hot Water Heating Boiler.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly