CVCS Flashcards

CVCS

1
Q

STATE the five functions of the Chemical and Volume Control System (CS).

A
  • Maintain the programmed water level in the pressurizer (ensure required inventory in the RCS)
  • Maintain the seal water injection flow to the RCP #1 seals
  • Control the reactor coolant water chemistry, radioactivity levels and concentration of soluble chemical neutron absorber (boron)
  • Provide emergency core cooling (High head portion of Safety Injection)
  • Provide a means of filling, draining and pressure testing the RCS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

DRAW and LABEL the Chemical and Volume Control System (CS) including major components and the related system flow paths

A
  • normal letdown and charging
  • excess letdown
  • RHR purification
  • ECCS injection and recirculation
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

STATE the function of the following CS component: Letdown level control valves (LCV-459 & 460)

A
  • Normal letdown isolation valves
  • Interlocked with CS-V-145
  • Auto Close:
  • Low Pressurizer Level ( 17%
  • CS-V-145 Full Closed
  • Air-operated, fail closed valves
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

STATE the function of the following CS component: Letdown isolation valve (V-145)

A
  • Interlocked with LCV-459/460 (both valves must be full open and pressurizer level >17% to open)
  • Keeps HX pressurized when placing in service or responding to a low pressurizer level/inadvertent LV-459/460 closure
  • Interlocked with Containment Isolation valves CS-V-149/150. Either valve “not full open” will auto close CS-V-145 which will prevent the relief valve from lifting
  • Air operated, fail closed
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

STATE the function of the following CS component: Letdown hand control valves (HCV-189 & 190)

A

drag valves, where pressure is reduced from operating pressure (2235 psig) to 350 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

STATE the function of the following CS component: Letdown containment isolation valves (CS-V149 & 150)

A
  • V149 is motor operated (IRC)/ V150 is air operated, (ORC) fail closed
  • Close on a T (Phase A) Signal and High Energy Line Break (HELB) isolation signal
  • Either valve “not full open” will auto close CS-V-145.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

STATE the function of the following CS component: Letdown pressure control valve (PCV-131)

A

• Maintains 350 psig pressure downstream of drag valves to prevent steam flashing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

STATE the function of the following CS component: Letdown high temperature divert valve (TCV-129)

A
  • Used to bypass Letdown and BTRS demins to prevent resin damage (> 165 °F).
  • Auto divert interlocks: letdown temperature >134 °F or inlet to BTRS demins > 157°F.
  • Air operated, 3-way valve controlled from MCB
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

STATE the function of the following CS component: Letdown divert valves (LCV-112A and LV-112A)

A
  • LCV-112A is an air operated, 3-way divert valve, fails to the VCT and is used when degasifier is not in service
  • Used to divert letdown to PDT
  • LV-112A is an air operated, 3-way divert valve, fails to the VCT
  • Used when degasifier is in service and diverts to BWST
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

STATE the function of the following CS component: Charging pump suction valves from VCT (LCV-112B and LCV-112C)

A
  • Isolate VCT from CCP suction

* Close on an SI and Lo-Lo VCT Level 5%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

STATE the function of the following CS component: Charging pump suction valves from RWST (LCV-112D and LCV-112E)

A
  • Open on low-low VCT level or SI

* Isolate the RWST from the CCP suction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

FCV-121

A
  • Controls total pump flow rate (charging + seal injection)

* Pressurizer master level controller controls position of FCV-121 when in auto

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

HCV-182

A

Controls seal injection flow rates by controlling the back pressure supply to the seals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

STATE the normal values for the following:
L/D flow and pressure
VCT temperature and pressure
Charging pump discharge pressure
Charging header flow
Seal water injection flow and temperature
Seal water return flow

A

 L/D flow and pressure 120 gpm / 2235 psig / 350 psig
 VCT temperature and pressure 90 °F/ 25 psig
 Charging pump discharge pressure: 2425 psig
 Charging header flow 132 gpm
 Seal water injection flow and temperature 32 gpm / 120 °F
 Seal water return flow 12 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly