Electrical Flashcards

1
Q

EPGDS?

A

Electrical power generation and distribution system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What makes up the DC system?

A

3 batteries
2 Engine driven starter generators
2 TRUs
1 APU
DC external power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the batteries?

A

3 Nickel Cadium (Nicad) batteries
40 amp hour
24 volts DC

Main, Aux, Standby

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the generators rated too?

A

400 Amps max

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many volts are the generators?

A

28.5 V DC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the TRUs max amp?

A

300
28 V DC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the APU max amps?

A

400

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

AC electrical system includes?

A

2 engine driven generators mounted in the prop reduction gearbox
AC external power receptacle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What do the AC gen’s produce?

A

115 V threes phase variable frequency AC power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

EPCU?

A

Electrical power control unit reconfigures the system if there is a power source failure or bus fault

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Can the AC gens power the whole electrical system

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where are the main and aux batteries?

A

Aircraft nose compartment left side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Are the main and aux battery used to assist engine starting even when external DC power is connected?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where is the standby battery?

A

Left nose compartment upper (in the compartment above the other two batteries)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Can the standby battery power the L DC MAIN BUS?

A

No one way power so it only gets charged

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Purpose of standby battery? (2 things)

A

Supply power to essential bus during an electrical emergency mode.
It also provides protection by absorbing voltage and current spikes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

How long Backup electrical power in flight provided by the batteries?

A

Approx 60mins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the hot battery bus powered by?

A

Standby battery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Battery Bus powers?

A

• CLOCKS ONE & TWO
• BATTERY MASTER SWITCH
• BATTERY POWER FOR REFUELING
• FIRE BOTTLES DISCHARGE SQUIBS
• FUEL & HYDRAULICS SHUTOFF VALVES
• ENGINE FUEL METERING UNITS
• CARGO COMPARTMENTS FIRE SYSTEMS
• APU FIRE BOTTLE SQUIB-MANUAL DISCHARGE
• FLIGHT DECK DOME LIGHTS & BOARDING LIGHTS
• EMERGENCY POWER-PASSENGER ADDRESS SYSTEM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Switched battery power bus is powered by?

A

Either main, aux or left ess bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What does the switcher batter power bus supply power to?

A

Electronic integrated standby instrument (EISI)
#1 VHF receiver and standby control head
Storm lights and CCT breaker lights
Back lighting for compass

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Turning battery master on does what?

A

Connects the 3 batteries to the essential buses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What batteries connect to the R ess bus?

A

Main and standby

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What does the aux battery connect to?

A

Left essential bus which also powers the switched battery bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

The EPCU is powered by?

A

Essential buses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

MAIN BATT switch on does?

A

Ties the main battery to the Right Main DC Bus and the switch batter power bus. Two way flow from main battery to right main dc bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

AUX BATT switch on?

A

Connects aux batt to Left Main DC bus and switch batter power bus.
Two way power flow between aux bay and left main dc bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

STBY BATT on?

A

Connects standby batt to the Left Main DC Bus. One way only to change to standby battery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

If there is a bus fault or during emergency electrical ops what prevents the batteries being connected to the Main DC buses?

A

EPCU logic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

Battery caution lights illuminated when?

A

When the battery are switched off or if there is an electrical fault and it has been automatically disconnect from its respective bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

How to monitor battery loads?

A

Electrical systems pages on either MFD (ENG SYS button)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

What lights will you get if there is a batter overheat?

A

Warning light
STBY BAT HOT
AUX BAT HOT
MAIN BAT HOT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Battery overheat temp?

A

> 71 degrees = warning lights
<63 degrees = warning lights extinguish

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

What are the 6 DC buses that are powered by external DC power on the ground?

A

2 Ess buses
2 main buses
2 secondary buses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

If the ground power over malfunctions (over or under voltage) what happens?

A

> 31 volts or <22 volts. The EPCU auto disconnects the external power source. After the malfunction is rectified then the DC external power switch need to be cycled which will also reset the EPCU protection logic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

What do the Gen 1 and Gen 2 switches do?

A

Control the engine driven DC started generators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

What position are Main to secondary bus ties prior to AC generators online?

A

They are closed to allow the secondary buses to be powered because the ac gens come online

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

Secondary buses powered by?

A

AC generators through the TRUs. To get the AC gens online the condition levers must be forward of 850 RPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

DC start Gen mounted?

A

Right side of the engines accessory gearbox and are air cooled

40
Q

Generator control unit (GCU) does what during the start?

A

NH >50% the GCU converts the starter generator from starter mode to generator mode

41
Q

GCU does what after start?

A

The GCU ensures generator supplies 28.5 volts DC and 400 amperes to it’s associated MAIN DC BUS

42
Q

What is the DC Gen load showing on the electrical page?

A

+1.00 means 100 % load on the generator.

43
Q

DC GEN caution light

A

Generator offline or Gen off

44
Q

DC GEN HOT caution light

A

Starter-Gen overheat. EPCU does not automatically remove the generator in this situation it must be turned off

45
Q

APU provides (volts)? And max load output?

A

28V AC
400 Amps

46
Q

TRUs do what?

A

Change 115V variable freq AC
to
28V DC 300 amp

47
Q

TRU supply power to which buses?

A

Secondary buses when AC Generator or external AC power is available

48
Q

If both DC starter gens fail can the TRUs power all the DC system?

A

Yes

49
Q

If the TRUE is offline or has failed what caution light will you see?

A

L or R TRU

50
Q

If the TRU is too hot what will you see?

A

L OR R TRU HOT. It will extinguish once temp decreases

51
Q

EPCU does what?

A

Monitors and protects by controlling 4 bus ties. Which can tie buses together when a DC generation source fails.
Main bus tie
2 Main to sec
Secondary bus tie

52
Q

If the Main Bus Tie switch is not tied but there is an DC Gen failure will the main bus tie close automatically?

A

Yes the EPCU will close it regardless of what the switch is doing

53
Q

If a TRU fails what bus tie will EPCU close?

A

Secondary bus tie

54
Q

If both DC Gens fail which bus ties will close for all buses to remain powered?

A

Secondary to main bus ties (vertical bus ties)

55
Q

Both TRUS failed what bus ties close?

A

Secondary to main

56
Q

Both TRU and single DC Gen all failed what happens?

A

EPCU auto load shed. Only main bus tie closed so only main buses are powered. Results in no secondary bus

57
Q

What is Emergency Mode of Operation?

A

EPCUs emergency mode occurs when airborne, DC gens not available and at least one TRU is not available

58
Q

EPCU emergency mode what happens?

A

Auto disconnect the main buses from the batteries.
Essential buses remain powered from the batteries
Secondary buses remain powered from remaining TRU
This is load shedding and loss of services from both main buses

59
Q

DC BUS caution light

A

Bus fault and the bus has been isolated by the EPCU and DC GCU protection
EPCU prevents the main and main to secondary bus tie from closing to isolate the bus

60
Q

DC BUS fault reset switch used when?

A

As per QRH when it is a stand alone caution light probably the result of a spurious electrical malfunction

61
Q

L Main Bus Fault - what caution lights illuminated?

A

DC BUS
STBY BATTERY
AUX BATTERY
#1 DC GEN

62
Q

R Main Bus Fault - what caution lights illuminated?

A

DC BUS
MAIN BATTERY
#2 DC GEN

63
Q

Secondary Bus Fault what CCT breaker will trip?

A

L or R TRU

64
Q

Can AC external power be used for engine starts?

A

No the TRUs have a 300amp limit and could be damaged

65
Q

AC gens supply what power and where are they mounted?

A

115V three phase variable frequency
Propeller reduction gearbox

66
Q

How are the AC gens cooled?

A

Oil cooled

67
Q

What system use 115V variable AC power?

A

De ice and anti ice heaters
STBY hyd pump
2 TRUs
# 1 and 2 Aux fuel pumps

68
Q

What caution light do you get if there is a failure of an AC Gen?

A

1 or # 2 AC GEN

Cross tie automatically happens to enable both left and right variable AC buses to be powered

69
Q

If a GCU detects a bus fault what will it do?

A

Isolate the bus. Meaning all services from effected bus are lost

70
Q

Gen overheat caution light?

A

1 or #2 AC GEN HOT

Must be turned off

71
Q

Can 1 AC Gen power the entire electrical system both AC and DC?

A

Yes!!

72
Q

During flight if both TRUs and a #1DC generator fail?

A

The secondary buses are shed

73
Q

Tripping of the L TRU circuit breaker may be an indication of

A

A left secondary bus fault

74
Q

Which of the following systems is NOT powered by the AC electrical system?

A

Cockpit display units

75
Q

Each engine driven state generator is rated at?

A

400amps

76
Q

The hot battery bus is powered by the

A

STBY battery

77
Q

The receptacle for external AC power is located?

A

On the inboard side of the #2 nacelle

78
Q

Battery hot warnings will occur when the battery temperature exceeds?

A

71 degrees

79
Q

During normal operations in flight the right secondary bus is normally powered by the

A

Right TRU

80
Q

The BUS FAULT RESET switch on the overhead panel may be used in response to a

A

DC BUS caution light

81
Q

The maximum battery load meter reading for takeoff is?

A

0.10

82
Q

During flight if both TRUs fail which bus ties will be closed?

A

Both secondary to main bus ties

83
Q

Illumination of the L TRU caution light indicates?

A

The TRU is not energised

84
Q

If there is an over voltage supplied by external DC power?

A

The EPCU automatically disconnects external power

85
Q

The APU starts generator is connected to the

A

Right main bus

86
Q

The DC generators are mounted to

A

The engine accessory gearbox

87
Q

Illumination of the DC BUS caution light indicates?

A

A DC bus fault has occurred

88
Q

The #1 engine starter generator is connected to the

A

Left main bus

89
Q

Selecting the MAIN BATT switch on directly connects the battery to the

A

Right main bus

90
Q

Illumination if the MAIN BATT HOT warning light indicates?

A

An overheat condition has been detected

91
Q

Illumination of the #2 AC GEN HOT caution light indicates an over temperature condition

A

The generator must be taken offline by the crew

92
Q

In flight how many sources of generated DC power are required to power all DC buses

A

Two

93
Q

Illumination of the MAIN BATTERY caution light indicates

A

The battery is not connected to the right main bus

94
Q

AC generators come online at approximately what propeller RPM

A

400NP

95
Q

The DC starter generators are cooled by

A

Ram air

96
Q

Selecting the MAIN BATT switch in connects the battery to the

A

Right main bus

97
Q

Where there is a bus fault or power source failure the DC electrical system is

A

EPCU