Module 5: Automatic Alarms Flashcards

1
Q

Which monitored alarms come through for CFA?

A

FIP and SPR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which monitored alarms come through for FRV58?

A

FIP
MCP
SPR
VMA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

672

A

Fire Indicator Panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

673

A

Manual Call Point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

675

A

Sprinkler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

676

A

Valve Monitor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

L1

A

Primary link failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

L2

A

Secondary link failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

EQ

A

Equipment fault

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

IS

A

Isolated status

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

AL

A

Alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

TE

A

Test mode

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

BT

A

Low battery fault

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the response for a VMA?

A

1 Primary C3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What must the radio dispatcher check before the last appliance is returning?

A

Before the last appliance returns from an automatic alarm event, the radio dispatcher must check whether
the ASE has restored to normal or has been isolated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

CFA/FRV27
When an automatic alarm is received in pending events and it restores to normal prior to dispatch, what workflow follows?

A

Update the event to a priority 3 response

Amend the Situation Comment to read “ALARM RESTORED TO NORMAL”

Recommend, dispatch and turnout

The radio dispatcher is to advise responding appliances of the details on turnout

17
Q

What is the CPS for processing automatic alarms?

A

The CPS for automatic alarms is 28 seconds

18
Q

What alarm monitoring companies monitor FRV/CFA alarms?

A

ADT
Romteck
Chubb/Code Red

19
Q

What does ASE stand for?

A

Alarm signalling equipment

20
Q

When an FIP operates in the CBD what is the response?

A

An enhanced response of three primary

appliances are to be dispatched

21
Q

When an Sprinkler Alarm operates full call in the CBD what is the response?

A

Three primary appliances and R3 are to be dispatched.

22
Q

If R3 is unavailable for a CBD Sprinkler full call. Does the response need to be fufilled?

A

A replacement Rescue is not required to be dispatched.

R3 is a non replaceable appliance.

23
Q

If an appliance or brigade requests to have an alarm isolated, the radio dispatcher is to gain what information to pass onto the alarm company?

A

Duration of isolation
Authorising officers name
Station
Officer’s rank

24
Q

What is the response for a SPR returned to normal prior to turnout?

A

1 Primary Code 1