Operating Fire Pumps and Tank Ops Flashcards
When doing daily inspection on pressure governor run pump to what PSI?
100 PSI
To maintain valves in working conditions you must open and close every valve daily to prevent what?
Mineral build up, accumulation of debris in waterways
OCFA Engine water tank size?
500 Gallons
OCFA Truck water tank size?
300 Gallons
OCFA Patrol water tank size
200 Gallons
NFPA 1901 Min. Standard for 500 GPM tank to pump Flow test
500 gpm pump or less should be capable of flowing 250 gpm from the tank
NFPA 1901 min. standard for pump greater than 500 gpm tank to pump flow test
Pumps with capacity greater than 500 gpm should be capable of flowing 500 gpm from the tank
Tank fill is capable of withstanding fill rates up to…
1000 GPM
NFPA 1901
Standard for automotive Fire Appaaratus
Per NFPA 1901 tanks less than 1000 gallons must have a tank-fill that is at least
1”
Per NFPA 1901 tanks larger than 1000 gallons must have a tank-fill that is at least
2”
How long can you flow an 1 3/4 SOS nozzle at 150 GPM on tank water
3 minutes
How long can you flow a 2 1/2” SOS nozzle at 250 gpm on tank water
2 minutes
Volume of water per 100’ of 4”
66 gallons 700’ of 4” will empty 500 gal tank
Volume of water per 100’ of 2 1/2
34 Gallons