SOG'S 500.00 - 509.00 Flashcards
Tampa fire rescue vehicles will not exceed the posted speed limit by more than ___ mph while on emergency runs, and only at that speed when conditions permit.
10 mph
501.00
“Near Miss” reporting system. Incidents where an unintentional unsafe occurrence could have resulted in an injury , fatality, or property damage.
WHAT FORM #
TFR 358
500.00
During EMERGENCY responses when should TFR vehicles come to a complete stop?
- Red light intersections
- STOP signs
- Negative right- of -way situations
- Blind intersections
- When you can’t account for all lanes in the intersection
- When other intersections hazards are present
- WHEN ENCOUNTERING A SCHOOL BUS WITH FLASHING WARNING LIGHTS
500. 01
When passing other fire emergency vehicles radio communications should occur 1st. What side is recommended to pass on?
Left Side
501.00
Drivers shall not operate TFR vehicles through flood waters above what?
above the axle
501.00
When laddering a roof the ladder selected shall be one that will extend __-__ft above the roofline.
2-3ft
502.01
If possible, when laddering a building under fire conditions, place the ladder near the ____ of the building. These areas are generally more stable in the event of a structural failure.
corner
502.01
When operating either above or below ground level, establish ___ separate means of egress where possible.
Preferably at ____ ends of the building or separated by considerable distance.
- 2
- opposite
502. 01
On the fire ground. All personal entering fire ground perimeter shall
what?
Wear full PPE
Carry portable radio
Leave PAR tags with the accountability officer at the entrance to the hazard area
Maintain crew integrity
502.02
On the fire ground a minimum team consists of ___ members.
2
502.02
Who can be the safety officer? Who assigns the safety officer?
Any individual
Command
502.03
At an emergency incident the safety officer shall have the authority to ___, ___, or _____ any activity judged to present an unsafe condition or imminent hazard to personnel.
Alter, suspend, or terminate
502.04
A safety group is under the direction of who?
Incident safety officer
502.04
This may be established at those incidents posing a high potential danger to personnel such as:
- Fire complexity
- HAZ-MAT
- Any where else this could be advantageous to the safety of the operation
SAFETY GROUP
502.04
In the typical fire ground building, the ___ is the most likely candidate for failure.
ROOF
502.04
Roof failure is typical for which 2 types of roofs?
Peak or Dome
502.04
Structures of other than fire protected / heavy timber construction are not designed to withstand the effects of fire, and can be expected to fail after approx. ___minutes of heavy fire involvement.
20min
502.06
If after ___-___ min of interior operations heavy fire conditions still exist, Command should initiate a careful evaluation of structural conditions and should be fully prepared to withdraw interior crews and resort to a defensive position.
10-15min
502.06
Teams of ___ or more members should conduct individual search activities.
2
502.07
When operating in a high-rise building where the potential hazards of falling glass and debris exist, a fire ground perimeter shall be established approximately ____ ft from the building and shall be observed by all fire personnel as a high hazard area.
200ft
502.08
Fire ground Full protective clothing shall be defined as Helmet with _____, _____, _____, ____,______, and ____
eye protection, bunker coat, bunker pants, gloves, boots and hood.
503.00
Personnel shall not use gloves that weren’t issued through the department.
The exception :
Departmentally approved rappelling gloves.
503.00
Commercial washing machines are available at stations ____, ____, & _____.
2, 13, & 21
503.01
Supervisors are to inspect employee’s protective clothing at least _____.
once quarterly
Each member of the fire suppression division shall be accountable for 1 SCBA and shall check that SCBA for condition at the ____ of each shift and after each____.
- Beginning of each shift
- After each use
504. 00
Each member shall physically perform a functional check of his/her S.C.B.A at the beginning of the tour of duty and complete the accompanying TFR ____ S.C.B.A apparatus report.
TFR 217
504.00
Who is responsible for the completion of the daily physical readiness checks of all unassigned S.C.B.A’s on his/her company.
Also is accountable for the completion of the TFR 217form for each unassigned S.C.B.A
Company Officer
504.00
Replacement SCBA’S are available through who?
VENT TRUCK DRIVER
504.00
Each member of the operations division will be assigned an individual S.C.B.A face piece and an _____.
A.P.R- Air Purifying Respirator
504.00
All personnel shall utilize S.C.B.A when encountering what emergencies?
- When involved in offensive fire ops
- Above and Below ground ops
- Contaminated Atmospheres
- Situations where it is likely the atmosphere may become contaminated
504. 00
It is generally true that _______ levels increase during overhaul, due to the incomplete combustion of smoldering materials.
Carbon Monoxide
504.00