1-1A-8 Flashcards

(26 cards)

1
Q

The distance between rivets in the same row, measured from center to center, should never be less than ____ _____ the shank diameter nor should it be more than ___ _____ the shank diameter.

A

four times; ten times

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The edge distance from the center of the rivet shank to the edge of the material should never be less than ____ the diameter, nor should it be more than ___ times the shank diameter.

A

twice; four

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Maximum angle of surface without spotfacing for rivet diameter 3/32-5/32.

A

20 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Maximum angle of surface without spotfacing for rivet diameter 3/16

A

15 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Maximum angle of surface without spotfacing for rivet diameter 1/4

A

10 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Maximum angle of surface without spotfacing for rivet diameter 3/16

A

5 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the most common rivet failure?

A

Shear failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the signs of a rivet failure?

A

Tipped heads, looseness and sometimes chipped or cracked paint

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What type of washer is used over an aluminum structure

A

Aluminum washer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where does the wear on cable mostly occur?

A

At pulleys

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the definition of a critical fatigue area?

A

working length of a cable where the cable runs over, under or around a pulley, sheave or through a fairlead, or flexed, rubbed or worked.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the critical fatigue area for cable with a swaged on fitting?

A

Within one foot.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A cable with how many broken wires in a critical fatigue area requires replacement?

A

One broken wire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A cable with how many broken wires in a non-critical fatigue area requires replacement?

A

At least three broken wires

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A rescue hoist cable with how many broken wires requires replacement?

A

One or more broken wires.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How must external corrosion on a cable be removed?

A

With a coarse weave rag or fiber brush

17
Q

What CPC is applied to a control cable?

A

MIL-C-16173, Grade 4

18
Q

Turnbuckle terminals be screwed into the barrel so that not more than ____ threads on the terminal are exposed.

19
Q

On initial installation, the turnbuckle terminals should not be screwed inside the turnbuckle barrel more than ____ threads.

20
Q

Wear on outer cable wires beyond 50% should be what?

A

Cable should be replaced immediately

21
Q

Wear on outer cable wires in between 40-50% should be what?

A

Cable should be replaced at the next convenient occasion.

22
Q

Wear on outer cable wires less than 30% should be what?

A

Cable does not require replacement.

23
Q

These terminals are used for attaching cables to quadrants and special connections where space is limited.

A

Swaged Ball Terminals

24
Q

What is the test load of a locally fabricated, reworked and repaired cable.

A

Apply a test load of 60% of the minimum allowable breaking strength gradually to one end of the cable.

25
While conducting a test load of a reworked or repaired cable, how long must the cable be under pressure?
3 minutes
26
Tube repair should not be attempted if damage occurs where of the assembly?
center one-third