100-135 Flashcards
(103 cards)
TB104 Urban Search and Rescue
NFPA 1670 -
NFPA Standard on Operations and training for technical rescue incidents.
TB104 Urban Search and Rescue
Who is responsible for the completion of the “permit entry”
Rescue group supervisor
*usually C11
TB104 Urban Search and Rescue
Non user companies may staff which crews on technical rescue incident. X3
Rigging crew, cutting crew, and ventilation
TB104 Urban Search and Rescue
There is a user task force in each division located at fs x6
3, 5, 27, 85, 88, 89
TB104 Urban Search and Rescue
The primary control method for atmospheric hazards is ____
Ventilation
TB104 Urban Search and Rescue
SAR: Supplied Air Respirators involve a separate air supply manifold, which is maintained by a Breathing Air Supply Monitor outside of the confined space. The rescuer is connected by air hose, up to a maximum of_____feet in length, to the air manifold
300ft
TB104 Urban Search and Rescue
All rescuers using supplied air shall wear an escape bottle, that shall normally be ____minutes of additional air to be used for emergency exit involving rescuers only.
10 min
TB104 Urban Search and Rescue
A copy of the confined space Rescue entry permits shall be forwarded to the department safety office and retained for ___ years from date of incident
5 years
TB 106 LCES
LLCCESS
Lookouts/location
Communication/conditions
Escape routes
Safety zones/ safety equipment
TB 106 LCES
Communication among members at an incident is always best when accomplished ____
Face to face
TB 106 LCES
Sounding the horn for ___ sec followed by ___ sec of silence and repeating this cycle ___ times for a total of ____ sec indicates that all companies need to retreat to their safe area.
10 &10sec
3 times
50sec total
TB 111 Elevator kit
Warning: when picking any elevator hoist way door , always _____
Shutdown power at mainline disconnect
TB 111 Elevator kit
Klein screwdriver with ___” tip and ____ 8”shank
3/8” tip and 8” shank
TB 111 Elevator kit
The pick up rollers are usually located within ___ to____from the leading edge of the door
8 to 12”
TB 111 Elevator kit
Kone equipment can sometimes be identified by their trademark, “_________”
Hall lantern
TB 111 Elevator kit
The pick may enter the interlock box which has up to ____volts AC when energized, and further emphasizes why the power must be shut down
230 volts
TB 111 Elevator kit
ThyssenKrupp pick
Typically there is a small slot in the plate which is located approximately ___ to ___ “ from the leading edge of the door.
3 to 4 “
TB 111 Elevator kit
When using the paddle, insert it through the door approximately ___ to ___ “ up from bottom of the door
6 to 12”
TB 111 Elevator kit
Which poling technique is most dangerous
Poling up
TB 111 Elevator kit
If the car floor is greater than ____feet above or below the landing it may be necessary to use alternate evacuation procedures or a rooftop exit.
3 ft
TB 111 Elevator kit
Step stool!
The lightweight foldable step stool is sturdy enough to support rescuers and may hold up to _____lbs
300lbs
TB 111 Elevator kit
Cleaning
Mix ___ tablespoons of mild laundry detergent or non antibacterial dish soap in spray bottle.
2 tablespoons
TB 111 Elevator kit
For replacement of non inventory item such as tags , ERK wedges or picks, send an email to LAFD._________@lacity.org
LAFD.elevatorrescue@lacity.org
Tb 113 Introducing the alameda corridor
In the mid Corridor section trains will descend into a 10 mile long( ____’ deep x ____’ wide)
33’ deep x 51’ wide