Containment Air Monitoring (CAM) Flashcards

1
Q

What are the primary Containment Air Monitoring System compoennts and their locations?

A

1) DW CAM - 1 per unit - RB517
2) DW/Torus O2 Analyzer - 1 per unit - RB 545
3) DW Rad Monitor - 2 per unit - DW Catwalk
4) Containment H2/O2 Analyzers (Post LOCA) - 2 per unit - RB 517
5) DW Sample Manifold - RB 545

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the design basis function of the Containment Air Monitoring System?

A

Monitor and prevent significant radiation, hydrogen and O2 buildup as indication of fission product release during LOCA;
Minimize risk of combustible atmosphere following DBA LOCA - Nitrogen inerting supports

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where is CAM monitored and what is the power source?

A

MCR 902-55(-56) - powered from MCC 28-2 (29-3)
- 29-3 lost during load shedding and will not be auto recovered upon Bus 29 restore. Bus 29 UV msut be reset and 29-3 breaker closed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is initiation logiv for CAM monitoring at local panels?

A

Rad detectors provide input to indicatores and recorders in MCR and alarm if DW monitors see 20R/Hr.
- Both A & B channels must see high drywell signal to cause Group 2 Isolation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where does the DW O2 analyzer pull from and return to?

A

Pull: RB Vent exhaust; DW Coolers 2E & G, and Torus

Returns back to DW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What signal impacts Oxygen analyzer and how does it respond?

A

Group II Isolation signal sends close signal to sample isolation valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the normal configuration of the Containment H2/O2 analyzers?

A

Normally in standby - initiated via CS initation logic to provide Post accident monitoring of DW and Torus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What Containment Air Monitoring Systems are functional following a LOCA?

A

The COntainment H2/O2 analyzers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where is the Drywell CAM?

A

RB 517

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What signals cause DW CAM to react and how does it react?

A

Closed on Group II Isolation, Loss of IA, or Loss of Instrument Bus.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the function of the Drywell CAM

A

Sample flows through charcoal cartridge and filter patper and is monitored by a detector to indicated DW environment conditions.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What causes a Group II Isolation?

A

DW Pressure +2psig
RX Level +8in
DW Rad Level 30R/Hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What are the set points for DW/Torus Rad Levels?

A

High Rad Alarm 20R/hr

G2 Isolation with both channels 30R/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is DW H2 Alarm Set?

A

3.5% - entry to DEOP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is DW O2 Alarm Setpoint?

A

3.5% - MAY VIOLATE TECH SPEC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly