APU Flashcards

1
Q

The APU is limited to ( ) only.

A

Ground use.

PTM 6-1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The APU provides ( ) and ( ).

A

Electrical power and pneumatic bleed air.

PTM 6-1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What 3 things will automatically happen in the event of an APU fire?

A
  1. Horn will sound
  2. APU will shut down
  3. Halon fire extinguisher will disperse

PTM 6-7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Will the APU Fire Push switch work with the aircraft batteries off?

A

Yes, because it’s wired directly to the Right Emergency Hot bus.

PTM 6-8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

After pressing the APU Master switch, how long must you wait prior to starting the APU.

A

10 seconds so it can complete its self test.

PTM 6-8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

After selecting the APU Bleed switch “ON”, there will be a ( ) before the white “ON” is illuminated.

A

several second delay

PTM 6-9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If the APU Fan Fail light in the tail cone illuminates, can the pilot attempt to reset it?

A

Yes

PTM 6-5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If the APU Fan Fail light in the tail cone is illuminated and cannot be reset, can the APU be used?

A

Yes, but only if the ramp temperature is 100° F or less.

PTM 6-5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

After normal APU shutdown, should you wait to turn off the APU Master?

A

Yes, 30 seconds while it runs a “BIT” test

PTM 6-11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The APU burns approximately ( ) from the ( ).

A

100 lbs per hour
Right wing tank

PTM 6-6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Can the APU still be used if the blue APU FAIL/FAULT light is illuminated.

A

Yes

PTM 6-13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Can the APU still be used if the APU ADD OIL or APU OIL LOW lights are illuminated? What’s the difference?

A

Yes. Must add oil within the next 5 hours of APU usage if OIL LOW light is illuminated.

PTM 6-13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What actions are required after the APU performs an un-commanded shut down?

A

A visual inspection must be completed prior to takeoff.

AFM 4-12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Can you takeoff with an amber APU FAIL CAS message?

A

No

AFM 4-12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The ( ) will automatically activate and remain on while the APU is running.

A

Right STBY pump

PTM 6-8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The waiting period between APU start attempts is

A

1 minute after the 1st attempt
2 minutes after the 2nd attempt
15 minutes after the 3rd attempt

AFM 1-24

17
Q

Max continuous amperage for the APU is

A

300 amps

PTM 6-11