Pneumatic Flashcards
4 pneumatic sources of power.
-Engine 1 bleed air system
-Engine 2 bleed air system
-APU
-Pneumatic ground air connection
________ bleed air comes from the 4th and 10th stages of high pressure compressor.
Engine
A _______ ________ ________ controls the 10th stage bleed air.
controlled by the (ASC) in the IASC.
Spring-loaded closed with the loss of electrical and Pneumatic power.
high pressure shutoff valve (HPSOV)
HP is 10th stage
An _______ _______ ________ prevents reverse flow into the 4th stage.
intermediate Pressure Check Valve (IPCV)
LP is 4th stage
_____ valves are spring loaded and electrically controlled.
PNU
_______ digitally controls the output of 4th and 10th stage pneumatic air in response to bleed system demands;
IASC (Integrated Air System Cooler)
The enable and disable coils on PRSOV solenoid valve are ______ ______ coils. When there is a loss of electric power, the solenoid valve stays in the last position given by an electrical command.
constant duty
If precooler outlet temperature reaches 400F (227C), the PRSOV will _____ bleed air flow (temperature topping).
The PRSOV commanded closed when precooler exit temperature reached 490F for 20s.
restrict
What is FAMV (Fan Air Modulating Valve)?
Butterfly valve that is spring loaded to the open pstn