T2 Part 2 Flashcards

1
Q

The term GLS means

A

General lighting service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A current flowing towards the viewer in a cross section of a conductor is
shown in a diagram by

A

A dot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Links are used across the joints of metallic trunking to

A

Maintain the continuity of the exposed conductive parts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What would be the effect of bringing the north seeking poles of two
magnets close together the magnetic fields would?

A

Repel each other

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Extra low voltage cables may be run in a steel trunking along with low
voltage cables provided that is :

A

They are run in separate compartments
within the trunking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Flemings right hand rule is used the direction of field current and force in

A

A Generator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The B type MCB will operate magnetically at

A

3-5 times its rated current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A single-phase motor “hums” but fails to start. One practical test is to check for the:

A

Continuity of the stator windings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

One of the main functions of a contactor is to ?

A

Provide no volt protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When threading conduit, the die should be turned in an anti-clockwise
direction at frequent intervals in order to :

A

Break up the swarf

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The voltage between any conductor and earth is. :

A

346 Volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The C type MCB will operate magnetically at :

A

5-10 times its rated current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The tables which give the continuous current carrying capacity of cables in
the ETCI rules are based on an ambient temperature of :

A

30°C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The maximum voltage allowed for portable hand tools used on a construction sites is :

A

115 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A Continuity test on a Pvc conduit would read. :

A

Infinity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly