2016 LAFD Arrow XT Flashcards
Blind spots can extend up to ____ feet in front and
____ feet behind a vehicle
16 ft (front) 160 ft (behind)
Do not work within 10 feet of high-voltage lines energized from ____ to ____ volt
600 to 50,000
High pressure hydraulic fluid at pressures as low as ___ psi can penetrate skin.
100 psi
Keep ___ ft from power line of the voltage is not known
50 ft
Keep __ ft from power line ____ kilovolts or less
50 ft if voltage is unknown
20ft from power line 350 kv
Anchor Failure hazard on aerial
Do NOT exceed _____ lbs
6000
According to 4-1.2 Ladder Assembly, the four-section steel ladder will extend to a height of ____ft or _____ft above ground at ___degrees
100 ft or 105 ft above ground at 75 degrees
The tip of the aerial has a _____ lb capacity at full extension, with a __-mph wind and discharging up to ____ gpm at ___ psi and with the nozzle in any position.
500
50 mph
1000 gpm at 100 psi
The aerial is equipped with an electrical swivel with ____ collector rings (32 collector rings optional), capable of operation through ___°.
28 collector rings
360°
Each collector ring is capable of handling a ___-amp load.
20 amp load
The EPU is used for limited ladder functions to stow the aerial in case of _____________.
primary pump failure.
The EPU can operate continuously for up to _______ mins.
thirty (30) minutes.
What type of Engine and Transmission does the Pierce Arrow XT tiller and Body Assembly have?
Engine - Cummins ISX 15 912CI (14.9L)
Transmission- Allison 4500 EVS
How much HP does the Pierce Arrow engine provide and at what RPM?
500 HP @ 1800 RPM
What type of alternator does the pierce arrow xt have? How many amps?
Niehoff C531 w/ Remote Regulator
360 amps
Vehicle Data Recorder (VDR). The VDR is capable of reading and storing the most recent ___ hours of vehicle information
100 hours
Jackknife collision warnings activate at ____° and ____° angles.
65° and 85°
Load Manager Indicator:
Low Battery illuminates
when voltage drops below _____ VDC. Fast Idle activates when voltage drops below ____ VD
- 9
12. 8
he VDR is capable of operating in a voltage range from ___VDC to ___VDC
8VDC to 16VDC
What’s the rated tip capacity?
500
This gauge indicates the hydraulic pressure available to
operate the aerial. The system standby (bias) pressure is ______. The maximum system pressure is _____ psi.
350 psi (+/-10 psi).
3000 psi.
The EPU should be used only when the main system________ is not operating
hydraulic pump
DO NOT run the EPU for more
than ____ minutes without allowing at least____ minutes for cooling dow
30 minutes ON/ 30 min cool down
Load capacities are based on following conditions: 4 conditions
- Apparatus is set up according to the operator’s manual and leveled to within safe operating limits.
- the ladder is fully extended and unsupported, 360° continuous rotation
- 50 mph wind condition
- For icy conditions, refer to manual