It is unlawful to enter building or structure in a manner that will reduce the number of exits required by code. The exception is detached one or two family dwellings and townhomes not more than… Stories above grade
Three
Every room or space used for assembly of… Or more shall have the occupancy load posted in a conspicuous place near the main exit or exit doorway
50
Occupancy load signs of use… Inch minimum letters?
1/2
When two or more utilize the same egress, the …?
More stringent requirements shall be met
Seating booth shall provide… Inch per person?
24
Exit access, when occupancy load is 501 to 1000 provide… Exits
3
Illumination, means of egress, provide… Foot candle 11 lux minimum
1
Emergency power supply can be powered by all the following
Generator
Unit equipment
Storage battery
Elevators are required on a building… Or more stories in height
4
Interior swinging doors shall not exceed… Pounds of force?
Five
Commercial and assembly occupancies, latches and locks to prevent operation are allowed but the door must state in… Inch lettering, this door to remain unlocked when space is occupied.
1 inch lettering
Panic hardware shall be provided when the occupant load is… Or more. 15 pounds of effort maximum to open the door
50
Placement of a exit sign shall be in maximum viewing distance of… Feet?
100
Exit signs shall have… Inch letter and 3/4 inch stroke
6 inch letter
Exit signs shall have… Lux candle illumination
54
Low level exit signs shall be placed… 2… Inches off the ground/Floor?
10 to 18
Low level exit signs for group I-3 shall be placed… to… Inches off the ground/floor
6 to 8
Exit access commercial occupancies, provide… Inches minimum
44
Interior exit stairwells identification signs are to be placed 5 feet above the ground and
are… x… Inches?
12 x 18
Interior exit stairwell identification, letters designating the identification of interior exit stairwell is… Inches
1 1/2
Interior exit stairwell identification, floor number must be… Or larger with 3/4 inch stroke
Five
Exit passageways, standard occupancy is provide 44 inch exits except that exit passageways serving an occupant load of less than 50 shall not be less than… Inches
36 inches
Exit discharge, minimum width is… Inches and obstructed height of 7 feet
44
Assemblies, minimum aisle width,… Inches when seating is on both sides
48 inches