additional infos 2 Flashcards

1
Q

What are the requirement for EA Credit Advanced Energy Metering for a C&S project?

A

Install a minimum of one meter per energy source per floor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

minor improvement LT Sensitive land protection : clearings

A

limited to one per 300 linear feet on average, not exceeding 500 SF each.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

what types of trees can be removed from wetland and water body buffers?

A
  • hazardous trees, up to 75% dead trees
  • trees less than 6 inches diam at breast height
  • 20% of trees more than 6” w/ condition rating of 40% or higher
  • trees under 40% condition rating
  • condition rating assessment by an arborist certified
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

what does into entryway systems?

A
  • permanently installed grates
  • grilles
  • slotted systems w/ cleaning underneath
  • rollout mats
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

what must be provided to prevent interior cross-contamination? (enhanced IAQ strategies)

A
  • min. 0.50 cm per sf (or as in prereq) to create neg. pressure
  • self-closing doors
  • deck-to-deck partitions or hard-lid ceiling
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

whats is included in additional enhanced IAQ strategies?

A
  • exterior contamination prevention (CFD modeling, Gaussian dispersion analysis, wind tunnel modeling, or tracer gas modeling
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

For MR Credit Construction and Demolition Waste Mgmt, what shall not be included in the calculations?

A
  • excavated soil
  • land-clearing debris
  • alternative daily cover
  • waste-to-energy not considered diversion (except for wood waste to biofuel)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the situations when the lighting boundary can be modified?

A
  • if project abuts public area, can be moved 1.5 m
  • if project abuts public roadway, can be moved to the center line of that boundary
  • if contiguous properties owned by same entity have same or higher LZ rating.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

what is the baseline water consumption for fittings and fixtures?

A
toilet : 1.6 gpf
urinal : 1.0 gpf
public faucet : 0.5 gpm
private faucet : 2.2 gpm
kitchen faucets : 2.2 gpm
showerheads : 2.5 gpm
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

what can have a watersense label?

A
  • tank-type toilets (WC)
  • water-using urinals
  • private lavatory faucets
  • showerheads
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the exception to provide mechanical ventilation to naturally ventilated spaces?

A
  • ventilation openings are permanently opened
  • ventilation openings have controls that prevent them from being closed during times of expected occupancy
  • naturally ventilated zone is not served by heating or cooling equipment
  • the system is an engineered natural ventilation system approved by the authority having jurisdiction
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The energy-related systems discover includes what variables?

A
  • site conditions
  • massing and orientation
  • basic envelop attributes
  • lighting levels
  • thermal comfort ranges
  • plug and process loads
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What must be demonstrated from the “implementation” into water-related systems for innovation credit?

A
  • demonstrate that at least 1 on-site nonpotable water supply source was used to offset at least 2 of the water demand components.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

what are the parking spaces that should not be included in the total parking capacity?

A
  • on-street (parallel or pull-in)
  • parking spaces for fleet and inventory vehicles (unless used by employees for commuting and business purposes)
  • motorbike or bicycle spaces
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When is a location considered to be an infill site?

A

If the percentage of previously developed area divided by total area minus streets, rights of ways and water is over 75% then it is an infill site.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If part of the site is found to have contamination, then _________________ within the LEED project is considered a contaminated site.

A

the entire area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

what are the restrictions for the use types?

A
  • a use counts as only one type (i.e. walmarts)
  • no more than two uses in ea. category may be counted
  • counted uses must represent at least three of the five categories
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

warehouses, surrounding density :

A
  • w/in 10 miles of main logistic hub
  • w/in 1 mile of on-off ramp to highway
  • w/in 1 mile driving o active freight rail ine
  • served by active freight rail spur
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Bicycle trails or lanes may be counted if they are fully funded by

A
  • the date of the certificate of occupancy

- scheduled for completion w/in one year of that date

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What is not required for bicycle storage when it comes to Schools?

A
  • short-term not required

- long-term includes staff and students grade 4 and above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is not required for showers when it comes to schools?

A
  • do not include students
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

When is preferred parking not required?

A

When no off-street parking is provided.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Give 6 examples of transportation demand management strategies

A
  • telecommuting
  • shuttles
  • shared parking between uses
  • residential units rented or sold separately from parking
  • transit subsidy
  • compressed workweek schedule
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What is required for submittal in reduced parking footprint?

A
  • drawings and photographs of signage or pavement markings indicating reserved status of preferred parking areas
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

What is the minimum score green vehicles must obtain and in waht rating?

A

45, ACEEE : American Council for an Energy Efficiency Economy

26
Q

What must be addressed in the local equivalent standards of the ACEEE?

A
  • particulate matter (PM)
  • nitrogen oxides (NOx)
  • hydrocarbons
  • carbon monoxide (CO)
27
Q

What is the requirements for SS Prereq Construction Activitiy Pollution Prevention

A
  • create and implement ESC (conform to EPA CGP)
28
Q

What are the requirements for SS Prerequisite Environmental Site Assessment and to what project types does it apply?

A
  • Conduct Phase I Env. Site Assessment.
  • Conduct Phase II if contamination is suspected

applies to vulnerable populations (Schools and Healthcare)

29
Q

What does a Phase I ESA includes?

A
  • review of historical records
  • site visit to visually identify potential contamination sources and signs
  • interviews w/ individuals
  • exec. summary indicating whether Phase II ESA is required + report
30
Q

What are the contaminants that are not part of the scope for a Phase I or Phase II ESA?

A
  • asbestos
  • radon
  • mold
  • lead, etc.
31
Q

Restorated disturbed or compacted soils should meet what requirements?

A
  • soils must be reused for same original function
  • imported topsoils or soil blends must not include NRCS protected soils or greenfields (unless byproduct of construction)
32
Q

Restored soils for SS credit Site Development Protect or Restore Habitat must meet what critera of reference soil?

A
  • organic matter
  • compaction
  • infiltration rates
  • biological fct OR chemical characteristics
33
Q

What are the conditions for an open space to count in a multitenant complex?

A
  • part of a master plan
  • must be protected from development
  • must be returned to natural state
  • combination of adjacent and nonadjacent open spaces can be used.
34
Q

What is the exemplary performance for SS Credit Rainwater Mgmt?

A

Manage 100% of rainwater that falls w/in the project boundary.

35
Q

What are the two options for SS Credit Heat Island Reduction

A

Opt. 1 : nonroof and roof

Opt. 2 : parking under cover

36
Q

Name nonroof measures.

A
  • shade w/ new or existing plants (in place at occupancy, 10-year canopy at noon)
  • vegetated planters (turf does not count, in place at occupancy)
  • shading structure w/ energy generation
  • shading architectural devices (0.28/0.33)
  • ## high-reflectance paving (0.28/0.33, consider maintenance)
37
Q

What is the equation for SS Credit Heat Island Reduction and what option # is it?

A

Option 1 :

A_nonroofmeasures/0.5 + A_highreflectanceroof/0.75 + A_vegetatedroof/0.75 >= A_totalsitepavingarea + A_totalroof

38
Q

For the calculation method for light trespass, the calculation points may be no more than

A

1.5 m apart

39
Q

The vertical illuminance calculation points must be no more than ____ apart and extend from grade level up to at least ____ above the tallest luminaire in the projet.

A
  1. 5 m

10. 0 m

40
Q

What are the systems that must be commissioned for EA Prerequisite Fundamental Commissioning and Verification

A
  • Mechanical, including HVAC
  • Plumbing including DHW
  • Electrical
  • RES
41
Q

Where must the envelope be covered?

A

In the BOD and OPR but full commissioning ioccurs in Credit Enhanced Commissioning

42
Q

Systems that do not need to be commissioned in the prerequisite

A
Envelope
Life safety systems
Communication + data 
Fire protection and fire alarm
Process equipment
43
Q

how long must the project experience extend for someone to work on a project as a CxA?

A

from early design phase to at least 10 months of occupancy

44
Q

in all cases, the CxA must

A

report findings directly to the owner

45
Q

What must a BOD include?

A
  • systems and assemblies
  • performance criteria + assumptions
  • descriptions
  • governing codes and standards
  • owner directives
  • design development guidelines
  • revision history
46
Q

What could indicate that Opt. 2 or Opt. 3 would be advantageous for a project in EA Prerequisite Minimum Energy Performance?

A
  • additional cost of energy modelling not warranted
  • budget and timeline could benefit simplified decision making
  • project type covered under one or both prescriptive options
47
Q

What could indicate that Opt. 1 for EA Prereq Min Energy performance would be advantageous to a project?

A
  • prescriptive paths not available b/c of project size or type
  • project has HVAC not convered by prescriptive paths
  • team wants to maximize points for EA category
  • efficiency trade-offs
  • calculations for carbon reductions and costs
48
Q

At what date must the qualified resources for EA Credit Green Power and Carbon Offsets must have come online?

A

January 1, 2005

49
Q

What are the accounting processes and standards that must be equivalent to Green-e products to be eligible?

A
  • verifiable chain of custody
  • verifiable age of renewable energy
  • tracking of HGH reductions from eligible projects
  • mechanism to prevent double-counting
  • 3rd party verified retail transaction
50
Q

What is cradle to cradle?

A

Emphasizes recycling and reuse at the end of life rather than disposal.

51
Q

Is furniture required to be included in the MR calculations?

A

No but if yes, it must all be included in all cost-based credits.

52
Q

What is excluded from the MR calculations?

A

elevators, escalators, process equipment, fire suppression systems, etc.

53
Q

Carpets of different pile heights are separate or same products?

A

separate because they are used for different kinds of foot trafic. (differnet color does not count as separate)

54
Q

Retail must identify top-X recyclable waste streams and demonstrate that Y amount will be diverted

A
X = 5
Y = 4
55
Q

Describe option 2 for MR Credit BPDO EPD

A

use at least 50% by cost of third party certified products that demonstrate impact reduction below industry average in at least 3 of the impact categories.

valued as 100%

56
Q

What are the additional requirements for Schools, Healthcare, Hospitality and Retail when it comes to WE Prerequisite Indoor Water Use Reduction

A

compliant products added :

  • dishwashers,
  • food steamers,
  • combo ovens.
57
Q

The checklist ensures that the systems have been

A

installed, started up, programmed, tested, and balanced and are ready for functional testing.

58
Q

How long can the project team wait before submitting the construction phase review?

A

No longer than 2 years after certificate of occupancy.

59
Q

What is included in a systems manual?

A

· Executive summary
· Owner’s project requirements
· Basis of design
· System single-line diagrams
· Construction record documents and specifications
· Approved submittals
· As-built drawings
· As-built sequence of operation
· Original setpoints for all systems commissioned
· Recommended schedule for recommissioning
· Recommended schedule for sensor recalibration
· Equipment operations and maintenance manuals
· Equipment preventive maintenance schedules
· Confirmation of completed training for the owner and occupants
· Ongoing system optimization procedures
· Final commissioning report

60
Q

The CFR and O&M plan must include

A

· Sequences of operation for the building
· Building occupancy schedule
· Equipment run-time schedules
· Setpoints for all HVAC equipment
· Lighting levels throughout the building
· Minimum outside air requirements
· Changes in schedules or setpoints for different seasons, days of the week, and times of day
· Systems narrative describing the mechanical and electrical systems and equipment
· Preventive maintenance plan for building equipment described in the systems narrative
· Cx program that includes periodic Cx requirements, ongoing Cx tasks, and continuous tasks for critical facilities

61
Q

What is included in the Cx Plan?

A

· Goals and objectives
· General project information
· Systems to be commissioned
· Team members, roles, and responsibilities
· Communication protocol, coordination, meetings, and management
· Reviewing the OPR
· Reviewing the BOD
· Developing systems functional test procedures
· Verifying system performance
· Reporting deficiencies and the resolution process
· Accepting the building systems

62
Q

When must the commissioning authority be engaged?

A

By the end of the design development phase. (not schematic-design)