LHR shall not exceed the limits specified in the COLR

Applicable:____________________

Actions:

A: COLSS Calculated core power exceeds COLSS LHR POL

A.1 Restore LHR to within limits

Completion Time:_________

B: LHR not within acceptable operation when COLSS is out of service

B.1 Determine Trend in LHR

Completion Time:______

AND¨

B2.1 With an adverse trend, restore LHR to within limits.

Completion Time:___________

OR¨

B.2.2 With NO adverse trend, restore LHR to within limits.

Completion Time:__________

C: Required Actions not completed

C.1 Reduce Power ____________

Completion Time:__________

A

LHR shall not exceed the limits specified in the COLR

Applicable:Mode 1 with Thermal Power >20%

Actions:

A: COLSS Calculated core power exceeds COLSS LHR POL

A.1 Restore LHR to within limits

Completion Time:1 Hour

B: LHR not within acceptable operation when COLSS is out of service

B.1 Determine Trend in LHR

Completion Time: Once every 15 minutes

AND¨

B2.1 With an adverse trend, restore LHR to within limits.

Completion Time: 1 hour

OR¨

B.2.2 With NO adverse trend, restore LHR to within limits.

Completion Time: 4 hours

C: Required Actions not completed

C.1 Reduce Power to =20%

Completion Time: 6 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The measured Planar RPFs (FMxy) Shall be = than the Planar RPFs (FCxy).

Applicable: _______________

Actions:

A: FMxy > FCxy

A.1.1: Adjust addressable CPC constants to increase the multiplier applied to planar radial peaking by a factor >/= FMxy/FCxy

Completion Time:___________

AND

A.1.2 Maintain a margin to the COLSS operating limits of [(FMxy / FCxy)-1] x 100%

Completion TIme:___________

OR

A.2 Adjust the affected FCxy used in the COLSS and CPCs to a value >/= measured FMxy

Completion Time:___________

OR

A.3 Reduce thermal power to ________

Completion Time:___________

A

The measured Planar RPFs (FMxy) Shall be = than the Planar RPFs (FCxy).

Applicable: Mode 1 >20%

Actions:

A: FMxy > FCxy

A.1.1: Adjust addressable CPC constants to increase the multiplier applied to planar radial peaking by a factor >/= FMxy/FCxy

Completion Time: 6 hours

AND

A.1.2 Maintain a margin to the COLSS operating limits of [(FMxy / FCxy)-1] x 100%

Completion TIme: 6 hours

OR

A.2 Adjust the affected FCxy used in the COLSS and CPCs to a value >/= measured FMxy

Completion Time: 6 hours

OR

A.3 Reduce thermal power to =20%

Completion Time: 6 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The measured Tq shall be = the Tq allowance used in the CPCs

Applicable: Mode 1 >20% power

Actions:

A: Measured Tq > allowance used in the CPCs and within the limit in the COLR with COLSS in service

OR

Measured Tq >the allowance in the CPCs and =.03 with COLSS out of service

A.1 Restore measured Tq

Completion Time:__________

OR

A.2 Adjust the Tq allowance in the CPC to >/= the measured value

Completion Time:__________

B: Measured Tq not within the COLR limit with COLSS in service

OR

Measured Tq>.03 with COLSS out of service

Note: Action B.5 must be completed is power reduction commences prior to restoring Tq)

B.1 Reduce Thermal Power ___________

Completion Time:________

AND

B.2 Reduce VOPT setpoint to <55%

Completion Time:_________

AND

B.3 Restore measured Tq to < Tq allowance used in CPCs

Completion Time:________

AND

B.4 Correct the cause for measured Tq not within the limit

Completion Time:________

AND

B.5 Subsequent to power operation _______ verify measured Tq is within the limit

Completion Time:________

C: Actions not met

C.1 Reduce power ____________

Completion time:__________

A

The measured Tq shall be = the Tq allowance used in the CPCs

Applicable: Mode 1 >20% power

Actions:

A: Measured Tq > allowance used in the CPCs and within the limit in the COLR with COLSS in service

OR

Measured Tq >the allowance in the CPCs and =.03 with COLSS out of service

A.1 Restore measured Tq

Completion Time: 2 hours

OR

A.2 Adjust the Tq allowance in the CPC to >/= the measured value

Completion Time: 2 hours

B: Measured Tq not within the COLR limit with COLSS in service

OR

Measured Tq>.03 with COLSS out of service

Note: Action B.5 must be completed is power reduction commences prior to restoring Tq)

B.1 Reduce Thermal Power =50%

Completion Time: 4 hours

AND

B.2 Reduce VOPT setpoint to <55%

Completion Time: 16 hours

AND

B.3 Restore measured Tq to < Tq allowance used in CPCs

Completion Time: Prior to increasing power

AND

B.4 Correct the cause for measured Tq not within the limit

Completion Time: Prior to increasing power >50%

AND

B.5 Subsequent to power operation >50% verify measured Tq is within the limit

Completion Time: Once per hour for 12 hours OR Until verified >/= 95%

C: Actions not met

C.1 Reduce power = 20%

Completion time: 6 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

DNBR shall be maintained by one of the following:

a. COLSS in service

  • Maintinaing COLSS calculated core power = to COLSS calculated DNBR POL when at least 1 CEAC is operable in each operable CPC OR
  • Maintaining COLSS calculated core power = to COLSS calculated DNBR POL decreased by an allowance specified in the COLR when the CEAC requirements aren’t met.

b. COLSS out of service

  • Operating within the region of acceptable operation specified in the COLR using any operable CPC when at least 1 CEAC is operable in each operable CPC channel
  • Operating within the region of acceptable operation specified in the COLR using any operable CPC channel with both CEACs inoperable

Applicability: Mode 1 with power >20%

Actions:

A: COLSS calculated core power not within limit

A.1 Restore DNBR within limit

Completion Time:_________

B: DNBR outside the region of acceptable operation when COLSS is out of service

B.1 Deterine DNBR Trend

Completion Time:________

AND

B.2.1 With an adverse trend, Restor DNBR

Completion Time:________

OR

B.2.2 With no adverse trend, Restor DNBR

Completion Time:________

C. Actions not met:

C.1 Reduce thermal power =20%

Completion Time:________

A

DNBR shall be maintained by one of the following:

a. COLSS in service

  • Maintinaing COLSS calculated core power = to COLSS calculated DNBR POL when at least 1 CEAC is operable in each operable CPC OR
  • Maintaining COLSS calculated core power = to COLSS calculated DNBR POL decreased by an allowance specified in the COLR when the CEAC requirements aren’t met.

b. COLSS out of service

  • Operating within the region of acceptable operation specified in the COLR using any operable CPC when at least 1 CEAC is operable in each operable CPC channel
  • Operating within the region of acceptable operation specified in the COLR using any operable CPC channel with both CEACs inoperable

Applicability: Mode 1 with power >20%

Actions:

A: COLSS calculated core power not within limit

A.1 Restore DNBR within limit

Completion Time: 1 Hour

B: DNBR outside the region of acceptable operation when COLSS is out of service

B.1 Deterine DNBR Trend

Completion Time: Within 15 minutes

AND

B.2.1 With an adverse trend, Restor DNBR

Completion Time: 1 hour

OR

B.2.2 With no adverse trend, Restor DNBR

Completion Time: 4 hours

C. Actions not met:

C.1 Reduce thermal power =20%

Completion Time: 6 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ASI shall be within the limits of the COLR

Applicability: ____________________

Actions:

A: Core average ASI not within limits

A.1 Restore ASI to within limits

Completion Time:_________

B: Actions not met:

B.1 Reduce thermal power to =20%

Completion Time:_________

A

Applicability: Mode 1 with power >20%

A.1 Completion Time: 2 hours

B.1 Completion Time: 4 hours