50 items MCQ Flashcards
(50 cards)
What is the minimum dimension for a
turning space in a water closet stall?
1.50 m
Who is empowered to administer the
provision of Rep. Act 1378?
The Board of Examiners for
Master Plumbers
What is the PRC Resolution Number is
issued by the Board of Master Plumbing
for the adoption and promulgation of
the Revised National Plumbing Code of
the Philippines?
Res. No. 4
A kind of cleanout plugs that will be
installed in case where raised heads
may cause hazards to passing personnel
or vehicles?
Countersunk
The following are grounds for non
issuance of the certificate of registration
by the Board of Master Plumbers
EXCEPT
Failure to pay the required fees
Who shall set the criteria for the quality
of drinking water from meteoric,
surface or underground sources?
National Standards for Drinking
Water
If a septic tank has a compartment that
exceed 3.7m in length, what should be
the additional requirement?
An additional manhole
Where the number of water closets in a
floor level exceed 20, how many of
these shall be provided to the disabled
persons?
2
What kind of concealed connections on
fixtures that it is required to provide an
access panel or utility at least 0.30
meter in its least dimension for easy
inspection and repair?
Slip joint
Which of the following could be omitted if the trap arm changes direction that does not exceed 90 degrees?
Cleanout
According to the Building Code of the Philippines, what is the range in height above grade should the Siamese fire department connection be installed?
30 cm to 1.2 m
What installation standard is followed in joining plastic pipe and fittings by solvent cement?
IAPMO
The appropriate sealant that will be used to cover void spaces between pipes and sleeves through concrete floors in the ground
Bitumen
In accordance to the Building Code, what must be provided in addition to septic tanks by building located in areas where there is no sanitary sewerage system whenever they will dispose their waste?
Subsurface absorption filed
Under the Accessibility Law, what is the minimum area of water closet stalls?
1.7 x 1.8 meters
When shall the installation of plumbing equipment to supply building or structures from existing water supply system only be allowed to?
When there is always water in the main
Under what law did plumbing became a duly recognized profession by the Philippine Government?
Jones Law of 1907
Who is authorized to issue rules and regulations to carry into effect the objectives of Republic Act 1378?
President of the Philippines
What should be done whenever a partition contains some piping and runs parallel to the floor joist underneath?
Double the joist
What is the minimum height of raised letters on an iron or bronze sign that will read “CONNECTION TO DRY STANDPIPE”?
20 mm
What is the minimum pipe size of the standpipe if the highest outlet is located more than 23 meters above the Fire Service connection?
6 inches
The Building Code stated that all dry standpipe outlet shall be equipped with valves having substantial chains. What kind of valve is this?
Gate Valve
What is the maximum distance as were supports of vertical cast iron soil pipes are made?
Every storey
Which of the following plumbing code in USA does the National Plumbing Code of the Philippines was being patterned for?
Uniform Plumbing Code