2012 IBC Flashcards

1
Q

Code governs mechanical equipment installed in an attic?

A

International Mechanical Code. 101.4.2.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Authorized and directed to enforce the provisions of the building code?

A

Building Official. 104.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When are building permits Required?

A

For new construction, reparis, or alterations. 105.1.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

One set of construciton documents must be kept?

A

Site of work. 107.3.1.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Wood columns for type IV shall have a nominal depth of not less than ______ where supporting roof and ceiling loads only?

A

8” 602.4.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Type of construction that permits exterior walls be to of any code permitted materials?

A

Type V. 602.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Combustible material permitted in Type I buildings?

A

Non-Bearing Partititions. 603.1.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Shaft enclosures shall have a fire-resistance rating of not less than how many hours for a story building?

A

One. 713.4.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Min fire door assembly rating for exterior walls where the required assembly rating is 1 hour.

A

3/4 hour. Table 716.6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What shall be installed to cut off concealed draft openings both horizontal and vertical?

A

Fire Blocking. 718.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Fire blocking shall consist of all of the following, but?

A

1 layer of 5/8” gypsum board. 717.2.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

For Group R-2, sprinkler what wall finish is required for corridors?

A

Class C. Table 803.9.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

In an apartment building that is four stores in height, sprinkler systems shall be installed and approved?

A

NFPA 13R. 903.3.1.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Not more than what percent of a ceiling area of a means of egress shall be reduced in height by protruding objects? ______

A

50%. 1003.3.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Emergency power systems shall provide power for a time of not less than?

A

90 minutes. 1006.3.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The minimum width of each door opening shall provide a clear width of not less than how many inches?

A
  1. 1008.1.1.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

The max threshold height of an egress door other than a sliding door is?

A

1/2” 1008.1.7.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Guards shall be located along open-sided walking surfaces that are located more than how many inches above the floor or grade below?

A

30” 1013.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Where doors swing into a bathroom, a clear floor space of not less than how many inches shall be provided within the room?

A

30” x 48” 1109.2.1.6.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What is the min. heigh of non-absorbent material from the finished floor around the toilet?

A

48”. 1210.2.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Minimum thickness of artificial stone?

A

1 1/2”. Table 1405.2.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is the minimum thickness of wood siding applied with no sheating?

A

1/2”. Table 1405.2.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Wood veneers on exterior walls of a Type III building shall not be less than what thickness?

A

1”. 1405.5.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Windows shall be installed in accordance with?

A

Manufacturers Instructions. 1405.13.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Where vinyl siding is intalled horizontally, the fastener spacing shall not exceed how many inches horizontally?

A

16”. 1405.14.1.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Vinyl siding is installed horizontally, what is the maximum vertical spacing of fasteners?

A

12”. 1405.14.1.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Horizontal fiber cement lap siding shall be installed with a minimum of ______?

A

1.25. 1405.16.2.

28
Q

Roof assemblies that are effective against severe fire test exposure?

A

Class A. 1505.2.

29
Q

What is the minimum slope of asphalt shingles?

A

2:12 or 17%, 1507.2.2.

30
Q

Which of the following fasteners is not approved for attaching asphalt shingles?

A

Bright Nails. 1507.2.6.

31
Q

What is the minimum overlap for a drip edge at the eaves?

A

2”. 1507.2.9.3.

32
Q

A cricket shall be installed on the ridge side of any chimney greter than?

A

30”. 1503.6.

33
Q

The minimum thickness of aluminum roofing panels is ____?

A

.024” Thick. Table 1507.4.3(1).

34
Q

The weight of a mechanical system is considered?

A

Dead Load. Ch.2 1602.1 (Definitions)

35
Q

A diaphragm transmits what?

A

Lateral Forces. Ch.2 1602.1 (Definitions)

36
Q

What is the minimum distributed uniform pounds per foot of live load for the corridors above the first floor of an office building?

A
  1. Table 1607.1.
37
Q

What soil inspection tasks require continuous verification by a special inspector?

A

Verify lift thickness during placement of controlled fill. Table 1705.6.

38
Q

What soil inspection tasks require continuous verification by a special inspector?

A

Verify lift thickness during placement of controlled fill. Table 1705.6.

39
Q

True regard a compacted fill material report, where the footings will bear on compancted fill material, but?

A

Field test method for determining the in-place wet density of the compacted fill. 1803.5.8.

40
Q

True regard a compacted fill material report, where the footigns will bear on compancted fill material, but?

A

Field test method for determining the in-place wet density of the compacted fill. 1803.5.8.

41
Q

In accordance with Modified Proctor the companced fill material should be compacted a minimum of?

A

90%. 1804.5

42
Q

If the bottom surface of the footings are greater than 10% and it’s necessary to change the elevation, the footing shall be?

A

Stepped. 1809.3.

43
Q

The minimum depth of footings below the undisturbed ground surface shall be?

A

12”. 1809.4.

44
Q

Minimum wall thickness for a plain masonry foundation wall that has a wall height of 8 feet and a maximum unbalanced backfill height of 6 feet with a soil class of GC is_________?

A

12” 1807.1.6.3.(1).

45
Q

Maximum vertical reinforcemetn for an 8” masonry foundtion wall with a maximum unbalanced backfill height of 8’-6” with a soil class of GW?

A

6 @ 48” on center. pages 401 and 359.

46
Q

What is the spacing for a 12” masonry foundation with reinforcing bars that have a wall height of 8’ and an unbalanced backfill height of 7’ with a soil class of SC?

A

6 @ 72” on center. 1807.1.6.3.(4).

47
Q

A 7.5” thick concrete wall that is 7’-6” high and supports 7’ of unbalanced fill, if lateral soil load is 45 psf, what’s the minimum required vertical reinforcement?

A

5 at 41” on center. 1807.1.6.3.2

48
Q

What is the maximum space of horizontal reinfrocement in detailed plain concrete structural walls?

A

72”. 1807.1.6.3.1.

49
Q

The top of a foundtion drain should be covered with?

A

Approved filter membrane material. 1805.4.2.

50
Q

Dampproofing shall consist of not less than 6-mil poly with joints lapped no less than?

A

6”. 1805.2.1.

51
Q

Masonry walls shall be parged on the exterior surface below ground level with no less than how many inches of Portland Cement and it shall be covered a the footing?

A

.375”. 1805.2.2.1.

52
Q

When required, waterproofing shall be applied from the bottom of the wall?

A

To not less than 12” above maximum elevation fo the ground water table. 1805.3.2.

53
Q

The minimum outside diameter for a driven open ended steel pipe should not be less than?

A

8”. 1810.3.5.3.2

54
Q

When is tied reinforcement placed in augered uncasted cast-in-place piles?

A

Prior to pouring. 1810.3.9.3

55
Q

What is the minimum specified compressive strenght for a driveway exposed to the earth under severe weather conditions?

A

3500 PSI. Table 1904.2.

56
Q

Concrete placed during hot and cold weather shall comply with the requirements of?

A

ACI 318. 1905.12.

57
Q

What is the minimum thickness of a concrete floor slab supported on the ground?

A

3.5”. 1907.1

58
Q

What is the allowable service load on an embedded 3/4 inch bolt wth an edge distance of 4-1/2” and a spacing of 9 inches with a minmum shear concrete strenght of 4000 pounds per square inch?

A

3,560. Table 1908.2.

59
Q

What is the minimum diameter fo pipe columns for construciton not exceeding 40 feet in height?

A

4”. 1912.5.

60
Q

What is the minimum length of end support for lintels shall be?

A

4” 2111.7.

61
Q

Minimum length of anchor rods that protrude through connection material?

A

flush with the head of the nut. 2204.2.1.

62
Q

Fire retardant treated wood shall be dried to a moisture content of what for wood structural panels?

A

15%. 2303.2.8.

63
Q

Which of the following truss modificaitons is permitted without written approval of a design professional?

A

Bracing. 2303.4.5.

64
Q

What is the maximum wall stud spacing of wood sheathing that is 5/8” thick?

A

24”. Table 2304.6.

65
Q

The shear capacity for horizontal wood framed gypsum board that has spacing of framing members at maximum of 16” on center _______minimum thickness of material?

A

1/2”. Table 2508.5