Oxygen Flashcards

1
Q

Which statement is true concerning the Oxygen System on the E190 aircraft?

A

Protective breathing equipment (PBE) is for emergency use only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Where is the Flight Crew Oxygen System bottle located?

A

In the forward cargo compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What occurs in the event of an over-pressure of the Flight Crew Oxygen Bottle?

A

A green discharge indicator disc located on the right forward fuselage skin blows out

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What type of oxygen masks are provided for the Flight Crew?

A

Full face, quick donning oxygen masks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How does a Flight Crew oxygen mask regulator function with the supply control knob in NORM?

A

Supplies oxygen diluted with cabin air on demand based on cabin pressure altitude

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is one important function of the EMER position of the Flight Crew oxygen regulator supply control knob?

A

To provide 100% oxygen under positive pressure to purge smoke and fumes from the mask

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How long will the Protective Breathing Equipment (PBE) oxygen supply last?

A

At least 15 minutes at altitudes up to 40,000 Ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How is oxygen provided for the Cabin Oxygen System?

A

Individual chemical oxygen generators located in each Passenger Service Unit (PSU), Flight Attendant
Station, galley areas, and lavatories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How long is oxygen provided to the passenger oxygen masks once oxygen begins to flow?

A

Approximately 12 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is important to remember concerning the masks in the Cabin Oxygen System?

A

The masks do not provide smoke protection and once they begin supplying oxygen, they cannot be shut off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How is oxygen flow provided to the passenger oxygen masks after mask deployment?

A

Oxygen flow begins to all masks connected to a dispensing unit whenever any mask from the dispensing
unit is pulled downward

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What does an illuminated ON light in the MASK DEPLOYED indicator mean?

A

That a signal has been sent to the passenger cabin to open the oxygen mask doors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What does the OFF position of the MASKS DEPLOY selector knob do?

A

Disables automatic deployment of the passenger oxygen masks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the purpose of the Purge Valve on the Flight Crew oxygen mask?

A

Allows oxygen flow into the face seal, purging any smoke and fumes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The Flight Crew sees a cyan colored 1000 in the MFD Status Page under OXY PRESS PSI. What does this mean?

A

Advisory that the oxygen system pressure is sufficient for 2 crewmembers in the flight deck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What do amber dashed lines indicate below OXY PRESS PSI in the MFD Status Page mean?

A

Invalid information or a value out of the valid operating range (no dispatch)

17
Q

What would be the correct Flightdeck Oxygen Pressure indication in the MFD Status page under OXY PRESS PSI
to tell the flight crew the Oxygen System is in the normal operating range (minimum for 3 crewmembers in the flight deck)?

A

Green colored digits

18
Q

What is the normal position of the Oxygen Supply Control Knob on each Flight Crew member’s oxygen regulator?

A

100%

19
Q

During the O2 & Interphone check on the Captain’s and First Officer’s Flight Deck Preparation Flow the Regulator
Control Knob is set to 100% and the TEST/RESET button is pressed and held. What’s the significance of ensuring
the Oxygen Flow Indicator shows a short illumination (or blink) and then goes OUT once the mask fully
pressurizes?

A

This ensures that the system is leak free

20
Q

The oxygen system parameters and indications are displayed on ____ page(s)

A

Both MFD Status Synoptic pages

21
Q

Pressing the TEST/RESET button with the crew oxygen mask stowed

A

Tests the oxygen mask and activates the microphone and speaker

22
Q

When the passenger mask doors are automatically or manually activated

A

Both A & C (An ON light illuminates on the PASSENGER OXYGEN panel, The FSTN BELTS and NO
ELEC DEVICES signs automatically turn on)

23
Q

The portable oxygen cylinders are for the use of flight attendants

A

To assist passengers in case of sudden decompression OR first aid purposes