Week 12 Flashcards

1
Q

What a report of a fire in an office building is confirmed what signal is transmitted?

A

10-76 FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When one hoseline is stretched and operating what signal is transmitted with the 10-76?

A

All hands. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When responding to a HROB fire, when is a second alarm warranted?

A

Fire or smoke emanating through the exterior skin of the building, or when serious fire has been verified.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Assigned as the Fire Sector Supervisor, you and your aide operate on what channels?

A

Fire Sector Supervisor on primary tactical, aide on command. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Assigned as the SAE Group Supervisor, you and your aide operate on what channels?

A

SAE Group Supervisor on secondary tactical, aide on command. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Assigned as the Forward Staging Area Manager you and your aide operate on what channels?

A

FSA Manager on command, aide on primary tactical. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A supply of how many spare cylinders shall be maintained at the Forward Staging Area?

A

At least 20. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Engine companies responding to the Forward Staging Area shall bring what?

A

A SCBA for each member, A standpipe kit and nozzle. Length of hose per member. Spare SCBA cylinder each member. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Ladder companies responding to the Forward Staging Area shall bring what?

A

SCBA each member. Two sets of FE tools and 6’ hooks. Search and utility ropes. Spare SCBA cylinder each member. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

T/F fixed ventilation systems located in stairwells should not be augmented by FDNY Positive Pressure Fans.

A

True. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Stack effect becomes noticeable in buildings over how many feet?

A

Over 60’ FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The fire sector/branch is considered what locations in the building?

A

Fire floor and floor above. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where should the SAE Group supervisor be located?

A

On a floor not served by the same bank of elevators as the fire floor and at least five floors above. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where should the Forward Staging Area be located?

A

Two floors below original fire floor. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where should the Forward Triage Area be located?

A

Environmentally safe location on a floor below the Forward Staging Area. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Local law requires fire alarm stations to be located no more than how many feet from the nearest one?

A

No more than 200’ FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What information should the first ladder company try and ascertain from the fire safety director?

A

LESA. Location of fire. Evacuation procedures. Status of elevators. Access stairs serving fire floor. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Who choses the attack stairway for a fire in a HROB?

A

First ladder officer. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

How does third ladder access the floor above at a HROB fire?

A

Stairway other than the attack stair. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What does the third ladder company report to the ICP at a HROB fire?

A

Heat and smoke. Status of evacuation. Extension. Access stairs to or from fire floor. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Where does the fourth ladder company go at a HROB fire?

A

To the roof. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What does the fourth ladder company report to the ICP at a HROB fire?

A

Smoke and heat in area and stairways. Occupants, means for roof vent. Unusual conditions. Fire or occupants visible from roof. FFP HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

When using two handlines for gross decontamination, what is the recommended nozzle?

A

Aquastream fog nozzle. HM7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

When using two handlines for gross decontamination, what is the recommended distance and pressure?

A

25-30’ and 50-80 psi. HM 7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

When using two pumpers for gross decontamination, what is the recommended nozzle?

A

Aquastream fog nozzle. HM 7

26
Q

When using two pumpers for gross decontamination, what is the recommended distance and pressure?

A

25’ and 50-80 psi. HM 7

27
Q

When adding a TL to the gross decontamination process what nozzle is used?

A

Turbomaster fog nozzle. HM 7

28
Q

When a TL is added to two pumpers, how big is the coverage area of the water spray?

A

20’ wide by 30’ long. HM 7

29
Q

If no TL is avail and it an AL is added to the gross decontamination process, what nozzle is used?

A

Aquastream on aerials. HM 7

30
Q

Upon arrival at a suspected chemical suicide incident, what signal is transmitted?

A

10-80-1. HM 11

31
Q

To operate as a Decon Engine, how many members need to be trained?

A

1 officer and 3 firefighters. HM 12

32
Q

To operate as a Soc Support Ladder, how many members need to be trained?

A

1 officer and 3 firefighters. HM 10

33
Q

What code do you transmit for a confirmed USPS BDS activation?

A

10-80. HM 14

34
Q

What HT channel is used to EMS and Fire communications?

A

Normal communications made on 1, primary tactical. Channel 10 is available for non fire emergencies to facilitate communications. Com 14

35
Q

What HT channels is used for NYPD and Fire communications?

A

13 Tac U. Com 14

36
Q

What wattage does Tac U transmit at?

A

5 watts. Com 14A2

37
Q

What are the five functions of ICS?

A

CFLOP. Command, Finance, Logistics, Operations, Planning. ICS 1

38
Q

When discussing ICS, what is the ideal span of control?

A

3-7 with 5 being ideal. ICS 1

39
Q

Can groups or sectors cross boundaries to accomplish functional tasks?

A

Groups can cross boundaries. ICS 1

40
Q

The Lobby Control Unit Leader shall verify the location of what areas?

A

Fire floor. FSA. SAE Post. Forward Triage Area. ICS 2A4

41
Q

What is carried in every car operated by a member of the LCU?

A

HT, FE Tools, Spare cylinder, Elevator keys, Search rope, Elevator Control Sheet, Clipboard. ICS 2A4

42
Q

Combustible materials may not be stored within what distance of a PCB Transformer?

A

Within 5 meters. AUC 266

43
Q

A permanent PCB storage site can have them on site for up to how long?

A

1 year. AUC 266

44
Q

A temporary PCB storage site can have them on site for up to how long?

A

Not exceeding 30 days. AUC 266

45
Q

What level of PCB exposure will cause implementation of decontamination procedures?

A

50 ppm or higher. AUC 266

46
Q

When discussing the Metro North M2 cars, which one has the pantograph?

A

The A or even numbered car. AUC 266A2

47
Q

What is the best way to identify M2 cars?

A

Orange stripe on side of car and pantograph on roof of A car. AUC 266A2

48
Q

Who is notified upon discovery of an illegal entry into quarters?

A

Admin BC and DC. PD. IG if Dept employee is suspect. BFI if it involves a false alarm. AUC 300

49
Q

When does the company commander review and sign the gear bag log?

A

Monthly in red pen. AUC 310

50
Q

Flight data recorders are generally located where in the fuselage?

A

In the rear. AUC 325

51
Q

Spherical recorders are painted what color?

A

Yellow. AUC 325

52
Q

Rectangular recorders are painted what color?

A

Red or International Orange. AUC 325

53
Q

When staging convoy fashion at an airport box, how do the units line up?

A

Engines on the right, everyone else on the left. AUC 325

54
Q

What color and pressure are the low pressure hydrants at LaGuardia?

A

65 psi black body with silver top. AUC 325

55
Q

What color and pressure are the high pressure hydrants at LaGuardia?

A

125 psi all yellow. AUC 325

56
Q

What color and pressure are the low pressure hydrants at JFK?

A

60 psi black body with silver top. AUC 325

57
Q

What color and pressure are the intermediate pressure hydrants at JFK?

A

90 psi black body with yellow top. AUC 325

58
Q

What color and pressure are the high pressure hydrants at JFK?

A

160 psi all yellow. AUC 325

59
Q

What is the greatest hazard in a PV system?

A

Shock from DC. AUC 351

60
Q

What are the Photovoltaic Components?

A

Cells, Modules, Array. AUC 351