subway ops Flashcards

0
Q

EED’s are located at base of emergency exits stairs nearest the under river tube AND near stations at the first blue light south of the station, on southbound track. Secured with TA locks

20lb dry chem extinguishers AND blue light phone located at power removal boxes ( every 600 ft )
All under river standpipe outlets are wet. / Standpipes are city main fed
Siamese’s are usually located at the emergency exits closest to the river
Section valves located 600 ft apart

TA portable radios: comm link can be used from the radio to the train master who then relays info to dispatch

A

.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Relay team

A

LCC : bottom of subway entrance stairs
OV : foot of stairs leading to platform
ROOF :approx 50 yards from stairs on platform
ENG OFF : Approx 100 yards ( line of sight ) from roof ff
LAD OFF : location of fire

Any additional members every 100 yards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly