Valves For Hp Geeco Flashcards

1
Q

A10

A

Controls head pressure, partially liquifies air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

N-2

A

Nitrogen expansion valves. Controls hp column pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

N-15

A

Product valve for LIN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

O5

A

Crude oxygen expansion valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

O6

A

Crude oxygen GAS expansion valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

O16

A

Crude LOX expansion valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

O8

A

Product valve for LOX

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Burst disk S7

A

Hp column 200 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Burst disk s9

A

Cold box, .22psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Burst disk s13

A

Waste n2 37-46

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Ts1 is used for what?

A

Derime

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Ts1 is the outlet heater for what? What is the range?

A

Heater x1, range is 550 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the outlet heater for s2? Range?

A

Ts3, 200 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is p3 range?

A

1800 to 1950 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does p4 moniter? Range?

A

Hp column pressure, 130 to 138psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What does p6 moniter? Range?

A

Lp column pressure. Range is 14 to 15psig

17
Q

What does p5 monitor? Range?

A

Hp column condenser, 80 to 90 psig

18
Q

Where is L1? Range?

A

Bottom of hp column, 3” to 4”

19
Q

Where is L2? Range?

A

Lp column, 9”-11”

20
Q

Where is L3? Range?

A

N2 sump, flooded

21
Q

What monitors waste n2 through x1?

A

M2

22
Q

S4 location and range

A

12b purifier 175 psig

23
Q

S5

A

Lp column, 25 psig

24
Q

S6

A

Waste n2 25psig

25
Q

S8

A

Hp column condenser 150 psig