Taxpayers Flashcards

1
Q

taxpayer
t/f
wood truss get spongey prior to failure

A

false, fail with no warning

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

taxpayers
sprinkler protection in sq/ft for following codes:
1938,1968,2008

A

1938= area exceeding 10,000sq/ft
1968= area exceeding 7,500sq/ft
2008=full building are exceeds 12,000sq/ft, combined area on all floors exceed 24,000sq/ft, occupancy within exceeds 7,500sq/ft, any area 3 stories above grade or in a high rise office, any area that has an unenclosed stair or escalator connecting 2 or more floors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

taxpayer

unprotected steel joist may collapse after __-__min

A

5-10min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

50’ steel “I” beam heated to 970degrees expand__”

A

50’ 970 degees expands 4”

*cooling a steel beam will regain strength

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

100’ steel “I” beam heated to 100degrees expands ___”

A

100’, 1000degrees expands 9.5”

*cooling a steel beam will regain strength

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

taxpayer
failure of which is the most severe
column, girder, or beam

A

column

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

taxpayer

a bowstring truss may only support __% of what it was originally designed to,

A

40%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

taxpayer

heavy fire may lead to collapse in __min

A

20min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

taxpayer

what size hole in the roof?

A

8’x8’ or as large as possible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

taxpayer

cellar fire where does the 1st line go?

A

must be stretched to the interior basement stairs, if conditions permit go down interior stairs.
*flooding 1st floor with TL streams or monitors are a last resort

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

taxpayer,

who ensures the sprinkler is supplied

A

3rd engine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

taxpayer

cellar fire, where does the 2nd line go

A

protect 1st line if they went downstairs, stretch to exterior cellar entrance if 1st line cant go down interior stairs.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

taxpayer,

where should the first 2 hoselines be stretched for a store fire? for a cockloft fire?

A

store/cockloft fire the 1st two hoseline should be stretched into the store

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

T/F
taxpayer
in the event of a cellar fire or serious 1st floor fire where ops are doubtful and a trench cut may be advisable as a defensive measure if it is feared fire will eventually get into the cockloft

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

taxpayer

at a store fire who brings a saw to the roof?

A

2nd roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

taxpayer

at a cockloft fire who brings a saw to the roof?

A

1st and 2nd roof bring a saw

17
Q

taxpayer

at a cellar fire when the 1st floor is going to be cut, where should you cut?

A

as close to windows as possible away from doors and aisles

18
Q

taxpayer

cockloft fire, where does the 1st line go when fire is extending to exposure? what if not extending?

A

if extending to exposure then into exposure that is most seriously exposed, if not extending then into store under main body of fire

19
Q

taxpayer fire

what ladder companies shall bring 10’ and 12’ hooks with them?

A

all ladders other then 1st and 2nd

20
Q

taxpayer

3 situations for a second alarm?

A

extension to cockloft, extension to adjoining occupancy, or advanced fire in cellar

21
Q

___% of a room or fire area contains explosive mixtur for the entire area to explose

A

25%

22
Q

taxpayer

who shuts down the utilites>

A

1st ladder inside team (2 members go as a team)

23
Q

taxpayer, cellar fire, where do the 1st 2 trucks operate?

A

1st ladder inside team - goes into store above fire

2nd inside team - to adjacent stores to check for extension, perform search

24
Q

who can order the ventilation of the store front window

A

IC