According to NFPA 1901, fire
department pumpers should have a
minimum pump capacity of:
750 gpm
After the driver/operator perceives the need to stop the vehicle, the distance the apparatus travels while the driver/operator transfers his or her foot from the accelerator to the break pedal is:
Reaction Distance
All aerial device movement should be
slow, smooth, and controlled because
of the:
force being
generated.
Apparatus equipped with a diesel particulate filter (DPF) will have:
very clean
exhaust emissions
and no black
smoke
Apparatus equipped with pressure
governors should be set in:
Pressure mode when acting as the attack pumper and RPM mode while working as a relay pumper.
An apparatus that is equipped with a fire pump,
water tank, and hose, in addition to an aerial
device and ground ladders, is BEST referred to
as a:
quint
The component in a load management system
that turns on various lights at specified
intervals so the electrical load for all devices
does not occur at the same time is called the:
load sequencer
The current formula for friction loss accounts
for the diameter of the hose, the volume of
water flowing and the:
length of the hose layout
The deck gun mounted to the engine has a 1
1/2 inch tip. What is the pump discharge
pressure?
90
During pumping operations driver/operators
should maintain a residual pressure on the
master intake gauge:
of at least 20 psi
During response to a possible hazardous
material incident, the apparatus should
approach from:
uphill and upwind
For a multistage centrifugal fire pump,
switching from volume to pressure.
can result in immediate doubling of previous discharge pressure.
For which of the following is a nozzle
pressure of 80 psi a safe and efficient
nozzle pressure?
Solid stream
nozzle (master
stream)
Generally, the maximum flow for a
handline is 350 gpm (1400L/min)
because greater flows will:
produce a nozzle reaction that is difficult or dangerous for firefighters to handle
How is the pumper position to supply
a fire department connection best
determined?
Through pre-
incident planning
If 300 gpm is flowing from a nozzle,
what is the total pressure loss due to
friction for 400 feet of 2 1/2 inch
hose?
72
If a sprinkler system is to be supplied at the fire department connections and no specific information is available, the general guideline is to discharge:
150 psi into the FDC
If discharge flow volume is increased too
much when operating from the
pressurized water source:
it may lead to
cavitation of the
pump.
If the building has been exposed to
severe fire conditions, it is MOST
advisable to park:
outside of
the buildings
collapse zone.
If water is not flowing for an extended
period of time during fire attack, why
might a circulator, bypass, or booster
cooling valve be opened on a pump?
To prevent
the pump from
overheating
In general, pumps supplying a relay
operation or master stream are used to
supply large amounts of water and
therefore require:
use of a parallel (volume) setting of the transfer valve.
In most jurisdictions, when civilian drivers
encounter emergency vehicles
responding with warning lights activated
and audible devices sounding they must:
pull to the right, stop, clear intersections, and remain motionless.
In order for apparatus to come to a
complete stop on snow and ice, it may
take:
3 to 15 times greater distance than it does on dry pavement.
In order to produce fire fighting foam,
what three items must be educated or
injected in correct ratios?
Foam
concentrate,
water, air