Hydraulic operating pressure on 5447
2800 (+- 50 psi)
Ladder pipe general extension, angle, pressure
70 degrees
75 feet
80 psi smooth bore
Which beam to extend first in a side-slope condition?
High side (upslope)
What is the maximum side slope angle for full load chart?
5 degrees
What is the maximum side slope angle for 50% load chart?
8 degrees
What is the maximum front to back slope for full load chart?
5 degrees
Minimum angle for level assist to work?
1 degree.
Level assist will not work if the apparatus is less than 1 degree out of level front to back or side to side.
4105, 4417, 4806 maximum angle
3.5 degrees
Seagrave emergency hydraulic pump steps
- Maxi brake
- Transmission in Neutral
- Aerial master ON
- Brake lock ON
- Engine OFF
- Ignition ON
- Emergency hydraulic switch in cab
- Press aerial enable foot pedal
- Hold joystick for desired operation
- Activate emergency hydraulic switch on turntable
- Allow pump to cool between operations
Pierce emergency hydraulic pump steps
- Maxi brake
- Transmission in Neutral
- Engine ON
- Aerial master ON
- Hold joystick for desired operation
- Emergency hydraulic switch on turntable
- Release EPU switch first then joystick
- EPU has 30 minute run time and 30 minute cool down time
Pierce electrical malfunction steps
- Use manual control valves behind access door on turntable to bed ladder
- Stow ladder
- Unlock 5th wheel
- Open manual stabilizer panel (to the right of normal stabilizer controls)
- Move diverter valve UP for stabilizer function
- Select desired stabilizer function and move valve