Air/Press/Vent Flashcards
(52 cards)
Following a pressurization SYSTEM 1 fault:
A. Master caution is activated and ECAM actions must be taken by the
crew
B. System 2 must be selected by the crew
C. System 2 takes over automatically without crew action
C. System 2 takes over automatically without crew action
The safety valves are operated:
A. Electrically
B. Hydraulically
C. Pneumatically
C. Pneumatically
Conditioned air is distributed to:
A. Cockpit, cargo bays, and cabin
B. Cockpit, forward and aft cabins
C. Cockpit, avionics bay, cabin
B. Cockpit, forward and aft cabins
What is the max negative differential pressure for the cabin?
A. 0 PSI
B. 1 PSI
C. 2 PSI
B. 1 PSI
Each one of the trim air valves optimize the temperature by:
A. Adding hot air
B. Adding fresh air
C. Modulation of pack flow
A. Adding hot air
What happens when the heating or cooling demand on one zone cannot be satisfied?
A. Engine thrust must be increased manually
B. The minimum idle is increased automatically
C. In any case, flight idle is sufficient
B. The minimum idle is increased automatically
Is it possible to use simultaneously Packs and LP ground unit
during long stops on a hot day?
A. Yes
B. No
C. Yes, if external temperature is > 50°c
B. No
When the “ditching” switch is selected ON, a closure signal is
sent to:
A. The outflow valve and the pack flow control valves
B. The ram air inlet and ventilation inlet and extract valves
C. All answers are corrects
C. All answers are corrects
The cabin zone temperature sensors are situated in the lavatory
extraction circuit and galley ventilation system.
A. True
B. False
A. True
The RAM air switch should be used:
A. At any time
B. Only when diff press is less than 1 psi
C. When diff press is greater than 1 psi
D. Only after outflow valve is fully opened
B. Only when diff press is less than 1 psi
When the landing elevation is set to AUTO, the landing
elevation is sent to the controller from:
A. FMGC
B. FCU
C. ADIRS
A. FMGC
The temperature selectors are located in:
A. The cockpit
B. The cabin
C. Both
A. The cockpit
To see the position of the outflow valve, it is necessary to call ECAM: A. COND page B. BLEED page C. PRESS page
C. PRESS page
Cabin pressurization starts at:
A. Engine start
B. Take-off thrust application
C. Lift-off
B. Take-off thrust application
In case of Pack Control valve failure:
A. Pack outlet temperature is controlled at fixed temperature
B. The pack is closed automatically
B. The pack is closed automatically
The pack flow control valve closes automatically in case of:
A. Pack overheat, engine fire push button released, engine start,
ditching p/b pressed
B. Bleed valve failure, pack outlet pressure increase
C. A and b.
A. Pack overheat, engine fire push button released, engine start
The purpose of the safety valve is to avoid:
A. Excessive positive differential pressure
B. Excessive negative differential pressure
C. A and B are correct
C. A and B are correct
Temperature regulation is automatic and is controlled by:
A. Zone controller
B. Pack controllers
C. A and B
C. A and B
In case of total zone controller failure: A. Hot air and trim air valves open and pack1 delivers air at fixed
temperature 15°c
B. Hot air and trim air valves close and pack 2 delivers air at fixed
temperature 15°c
C. Hot air and trim air valves close, packs deliver air at fixed
temperature (pack1 at 20°c and pack 2 at 10°c.)
C. Hot air and trim air valves close, packs deliver air at fixed
temperature (pack1 at 20°c and pack 2 at 10°c.)
Hot air pressure regulating valve:
A. Regulates the pressure of hot air tapped upstream of the packs
B. Is spring-loaded open in the absence of air
C. Opens automatically in case of duct overheat
A. Regulates the pressure of hot air tapped upstream of the packs
In automatic control mode, cabin pressurization is optimized
using information from:
A. FMGS cruise level, time to climb and static pressure information
B. Actual cruise level
C. Selected cabin altitude rotary switch and FMGS landing elevation
A. FMGS cruise level, time to climb and static pressure information
If a pack N 1 controller fails, the pack outlet temperature is regulated to: A. 10°C B. 18°C C. Between 5°C and 30°C
C. Between 5°C and 30°C
The outflow valve is powered in normal operation (no failure) by:
A. One out of two electric motors
B. One out of three electric motors
C. Three mechanically linked electric motors
A. One out of two electric motors
RAM air inlet, when set to ON will open:
A. In any case
B. Provided ditching is not selected
C. Provided delta P < 1 PSI and ditching not selected
C. Provided delta P < 1 PSI and ditching not selected