A.i.t PREP Flashcards

(58 cards)

1
Q

Typical overhang for counter top kitchen cabinets

A

19-25mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Type of hardware to hold up top mounted door

A

Lid stay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Standard height for closet rod

A

1600-1700

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Standard height for kitchen counter top/base units

A

915

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Bathroom vanity height

A

815

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Lower kitchen cabinet depth

A

610

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Correct order for plam built on site

A

Ends front top

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Standard width for a dishwasher opening

A

610

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Standard depth for upper kitchen cabinet is

A

305mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Space between upper and lower kitchen cabinet

A

350-450

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Shelving for linen closets

A

19mm thick

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where to shim for cabinets

A

Longest dimension diagonal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where does racking occur

A

Mounting wall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Common rafter shortenings

A

1/2 thickness of the ridge

Full thickness of fascia

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Valley rafters and supporting valley rafters

A

Contact the ridge and the cap plate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Supported valley rafters contact

A

Supporting valleys and cap plate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Valley jacks contact

A

The ridge and valley rafters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Valley cripple jacks run between

A

Supporting and supported valley rafters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Hip valley cripple jacks run between

A

Hip and valley rafters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Hip rafter shortening

A

1/2 45 degree thickness of common rafter

Full 45 thickness of fascia

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Supporting valley shortenings

A

1/2 the 45 thickness of the ridge Full

Full 45 thickness of fascia

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Supported valley shortenings

A

1/2 thickness of supporting valley

Full 45 thickness of fascia

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Hip jack rafter shortening

A

1/2 thickness of hip rafter

Full thickness of fascia

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Valley jack rafter shortening

A

1/2 thickness of ridge

1/2 45 of valley rafter

25
Valley cripple jack rafter shortening
1/2 45 thickness of supporting valley 1/2 45 thickness of supported valley
26
Hip valley cripple jacks shortening
1/2 45 thickness of hip rafter 1/2 45 thickness of supporting valley
27
Walkways and ramps must be atleast
600mm wide
28
Min height for handrail for temp walk ways and ramps
920-1070 Toe board installed @3.5m or workers below
29
Construction stair way requirements
Min 600 wide Must have handrail 800-920 above the lead edge of tread
30
Rung spacing for construction ladders
250mm-300mm
31
Wall mounted handrails heights
865-1070
32
Balustrade height (referred to as a guard)
The hand rail must be 900measured vertical from lof and 1070mm (900mm within dwelling unit)
33
Exterior balustrade height
Must be increased to 1070 when landings are over 1800mm high above grade
34
Out feed table to low=
Snipe
35
Inside unit run for winder stairs
No minimum
36
Hip/valley rafters should be how much bigger then commons
50mm
37
Ceiling joist supporting roof load should be how much bigger
25mm deeper
38
Maximum size of aggregate in floor slabs
1/3 slab thickness
39
Hallway width minimum
860
40
Hallway width barrier free
920
41
Knee space height
685
42
Knee space width
760 wide
43
Knee space depth
485
44
Out feed table too high =
Taper
45
Golden ratio
1:1.618, 8/13
46
What should you adjust to achieve consistent overhang and facia dimensions?
Adjust the minor roof
47
Minimum drawings required for permits
Site plan elevations of the building floor plans sections and details
48
The cost of a permit is typically based on
Floor area and percentage of the project cost
49
Minimum unit run at inside stringer
150 mm
50
Average unit run at the centreline of the stairs, must be
Minimum 200
51
Average unit run at the centreline of the stairs, must be
Minimum 200
52
Headroom for spiral stairs
1980 mm
53
Common stair turns
135° 180° 235°
54
The clear width between handrails for a spiral stair must be a minimum of
660 mm
55
Spiral stair, maximum unit rise
240 mm
56
Spiral stair, maximum unit rise
240 mm
57
What is the preferred angle of stairs?
Between 30 to 35°
58
The handrail height for a balustrade must be a minimum of
900-1070