1

GENERATOR LEFT (RIGHT)

GEN not connected to SEC BUS

2

INVERTER NO 1 (NO 2)

voltage < 90 volts
-- or --
output < 20 watts

3

FUEL LEVEL LEFT (RIGHT) TANK

collector tank below 120 lbs

Action:

Fuel Feeding Lever . . . CROSSFEED
Booster Pumps . . . ALL ON

4

FUEL SHUTOFF VALVE LEFT (RIGHT)

illuminated when electrical valve (operated by FUEL SWITCH) mounted on the aft of the fire-wall is closed

5

FUEL PRESSURE LEFT (RIGHT) ENGINE

fuel pressure decreasing below 3.5 psi

extinguishes above 7 psi

6

PITOT HEAT LEFT (RIGHT)

failure

7

WINDSHIELD LEFT (RIGHT)

temperature regulator failure

8

AIR INTAKE LEFT (RIGHT)

failed to open with ENGINE INTAKE switch ON

9

CHIP DETECTOR LEFT (RIGHT)

metal detected in gear case

10

OIL PRESSURE LEFT (RIGHT)

oil pressure < 40 psi

11

SRL & START LEFT (RIGHT)

illuminates when EGT not conditioned by computer

12

AUX INVERTER

voltage < 90 volts
-- or --
output < 20 watts

13

UNSAFE DOOR

illuminates if any of the doors are not securely closed

14

OVERSPEED

200 knots detected by F/O pitot-static system
accompanied by aural cockpit horn