AOCT April 25 Flashcards
(15 cards)
What are the differences between the SI and blackout sequencers dealing with the SWBP
On SI SWBP starts as soon as the SW pump at 20 seconds.
On B/O must have 30psig on the suction of the SWBP after 20 seconds before they come on
CV spray suction sources?
RWST until starting lineup at 27% to take suction from the sump
NaHO purpose (CV spray)
ensures pH of 8.5 to 11.
iodine removal
MDFP and EDFP auto starts?
MDFP starts on 100psig (+/- 5)
EDFP starts on 90psig (+/-5)
100 gals a min leak from Spent Fuel
100 gallons a leak leads to AOP/EOP
Anything below this is recoverable from OPs
How to unblock an SI
If Pzr pressure goes back above 2000psig, or if above 543 degrees
Auto Spray vs Manual spray
Spray
Phase B
SI (only on Auto)
Steam line isolation (only on auto)
Suction and power for the demin pump
MCC-8
CST
Polishing and primary mix bed
Flow rates: 75-150, 75-300
CST levels
50% admin for SBO
26% ITS min.
When 1 S/G reaches 75% what happens?
Shuts FRV, Trips MFPs, and trips the turbine
Feed reg valves are what?
Reverse acting
Souping
running less than 25% causing build up of oil in exhaust system
electrical line up
4kv to IBs
MFP oil pressures
Low Lube oil pressure trip 6psig
Oil pump starts at 8.5psig
Oil pumps stops at 12.5psig
MCC-4, MCC-3
Needs 8pisg to start