ASTM C173/C173M - Air Content of Freshly Mixed Concrete by the Volumetric Method Flashcards

(39 cards)

1
Q

Volumetric method covers determination of the air content of freshly mixed concrete containing what types of aggregates?

A

All types of aggregates, whether it be dense, cellular, or lightweight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Volumetric method measures the air contained in the _______ fraction of the concrete, but is not affected by air present in porous aggregate particles.

A

Mortar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

This test method requires the addition of _______ when the meter is initially being filled with water, so that after the first or subsequent rollings little or no _____ collects in the neck of the top section of the meter.

A

Isopropyl alcohol

Foam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

After the initial rolling of the meter, If more foam is present than that equivalent to ___% air above the water, the test is declared _______ and must be repeated with a larger portion/quantity of _______

A

2%
Invalid
Alcohol

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Air content of hardened concrete may be _______ or _______ than that determined by this test method.

A

Higher or Lower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Measuring bowl must have a diameter that is equal to 1 to 1.25 times the ______________

A

Height of the measuring bowl

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

TRUE or FALSE:

Measuring bowl shall not have a capacity of less than ___ L [ ___ cu. ft]

A
  1. 0 Liters

0. 075 Cubic Feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Top section of the meter shall have a capacity at least ___ % larger than the measuring bowl

A

20%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Top section of the meter shall be equipped with a transparent scale, graduated in increments not greater than ___%, from ___ at the top, to ___, or more, of the volume of the measuring bowl.

A

.5%
0% at the top
9%, or more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Gradations of the scale shall be accurate to ___ % by volume of the measuring bowl.

A

0.1%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Funnel shall be long enough to extend to a point just _____ the bottom of the top section.

A

Above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Tamping rod to be ___ diameter, and be at least ___ inches greater than the depth of the measuring bowl, but not be greater than ___ inches long.

A

5/8” diameter
4 inches greater
24 inches long

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Strike-off bar can be steel or plastic.

Steel strike-off bar dimensions are (at least):
__ inches thick, __ inches wide & __ inches long

Plastic strike-off bar dimensions are:
__ inches thick, __ inches wide & __ inches long

A
Steel = 1/8" x 3/4" x 12" long
Plastic = 1/4" x 3/4" x 12" long
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

TRUE or FALSE:

Tamping rod shall have the tamping end, or both ends, rounded to a hemispherical tip of the same diameter as the rod.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Calibrated cut to have a capacity of, or being graduated in increments equal to ___ % of the volume of the measuring bowl of the air meter

A

1.00% [+/-.04%]

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When is the ONLY time the calibrated cup is needed, and why?

A

When the concretes air content exceeds 9%.

The calibrated cup of water is used to bring the water level back into range of the scale.

17
Q

Measuring vessel for alcohol to have a minimum capacity of at least __ pint

A

1 pt (500 mL)

18
Q

Rubber syringe having the capacity for at least __ ounces

19
Q

Pouring vessel for water shall have a capacity of approximately __ qt.

20
Q

Mallet to have a mass of _______

A

1.25 lbs. [+/-.5 lbs]

21
Q

Calibrate the meter _______ and ________, or whenever there is a reason to suspect damage or deformation.

A

Initially

Annually

22
Q

Obtain sample of freshly mixed concrete in accordance with practice ASTM _____

23
Q

Fill measuring bowl with concrete in ____ layers of approximately equal volume.
Rod each layer ____ times.

A

2 layers

25 times

24
Q

After each layer has been rodded, tap the sides of the bowl with a mallet ___ to ___ times.

A

10 to 15 times

25
After tapping the sides of the bowl after the final layer, a slight excess of concrete of ___ mm [___ in] or less is acceptable. TRUE or FALSE: Add or remove a representative sample of concrete if necessary to obtain the required amount of concrete.
3 mm [ 1/8 inch ] TRUE
26
Wet inside of the top section, including gasket, prior to attaching to bottom section. Insert ______. Add at least ___ L [___ pt] of water followed by selected amount of alcohol.
Funnel | 0.5 L [ 1 pt ]
27
Do you add or subtract the Alcohol Correction Factor from the final air reading?
Subtract
28
Alcohol Correction Factors: 2 pints or less = 0% correction 3 pints = ________ correction 4 pints = ________ correction 5 pints = ________ correction
3 pints = 0.25% alcohol correction factor 4 pints = 0.50% alcohol correction factor 5 pints = 0.75% alcohol correction factor
29
If air content exceeds 9% air, add water using the _________ until water is visible in the graduated range.
Calibrated cup | which is equal to 1.00 +/-.04% of the measuring bowl
30
The number of calibrated cups of water will be _____ to the final air reading.
Added
31
After alcohol has been added, fill the graduated scale up with more ______. How much do you add? What are the next three steps?
Water. Add enough water to get it close to the 0% mark on the graduated scale 1 - Remove the funnel. 2 - Use the rubber syringe to add water to the point that the bottom of the meniscus is level with the 0% mark on the graduated scale. 3 - Place the watertight cap
32
After watertight cap has been placed, invert the meter and shake horizontally in ___ second intervals for the next ___ seconds. This process is meant to free the concrete from the measuring bowl.
5 second intervals | 45 seconds
33
After inverting meter for 45 seconds, tilt the meter ___ degrees and rotate the meter with hand 1/4 to 1/2 turns back and forth, occasionally turning the bowl 1/3 turns. How long does this need to be done?
45 degrees | 1 minute
34
After rolling the meter for 1 minute, set the meter upright and remove the ________. Then, allow the pressure to ________. The liquid level is considered stable when it does not change more than ___ % air within _____ minutes.
Watertight cap. Stabilize 0.25% air 2 minutes
35
After initial air % has been recorded, what is the next step?
Place the watertight cap back on and repeat the rolling process for 1 more minute
36
After second rolling of the meter has been completed, remove the watertight cap and allow the pressure to stabilize for ____ minutes. Once the air stabilizes, and if it is within ___% of the initial reading, read the bottom of the meniscus to the nearest ___% and record this as your final reading.
2 minutes | 0.25%
37
If after the second rolling, the pressure DOES NOT stabilize within ___ minutes, you need to close the watertight cap and roll for a third and final time. If the pressure stabilizes within 2 minutes, read the bottom of the meniscus to the nearest _____%.
2 minutes | 0.25%
38
After the third rolling, if the air does not stabilize (after 6 total minutes), _______ the test and start a new one using a new sample of concrete.
Discard
39
If there is more foam than that equivalent to 2 full percent air content over the liquid level, _______ the test and start a new one using a larger addition of ________.
Discard | Alcohol