AUC150 Iroquois Natural Gas Pipeline At Hunts Point Facility Flashcards

(24 cards)

1
Q

Iroquois pipeline consists of primarily how many pipes and what size?
Is made out of?
1.1

A

One pipe
24 inch (OD)
High strength steel

Buckeye is 2 12”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Is natural gas considered nontoxic? 1.1.

A

Yes 

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Is natural gas lighter than air?
1.1

A

Yes
PS Buckeye pipeline vapors are heavier so it seeps into low lying areas.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Natural gas can be an asphyxiant as it replaces oxygen, combustible in concentrations from approximately
—- to —- and will naturally disperse into the atmosphere.
1.1

A

5% to 15%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Is natural gas odorless and colorless in its natural state? 1.1.

A

Yes
However, more mercaptan is added to give the gas its odor for detection purposes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Iroquois pipeline.
What action does FD personnel have to do when dealing with automatic valves?

A

No FD action required
3.1.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Iroquois pipeline.
Automatic valves, also have manual shutdown capabilities.. In the event these valves require manual shutdown this can be performed by? 3.1.1.

A

ConED/Iroquois qualified personnel when ordered by FDNY IC.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Iroquois pipeline.
T/F
The larger cabinets contain two sets of controls to manually open or close the valves by utilizing the gas pressure in the pipeline or by hand pumping the valves
3.2.1

A

False
The smaller cabinets.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Iroquois pipeline the valve requires ——- full turns to close.
3.4 point

A

213 full turns

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

T/F
Iroquois pipeline.
No valve should be open or close without the approval of the FDNY
IC in consultation with ConEd/Iroquois personnel
4.5

A

False
Except in the event of immediate threat to life or property.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Iroquois pipeline. Each 1st through 3rd alarm units have been issued 2 Unit alarm assignment/instruction cards. One card shall be carried on the apparatus. The other card shall be placed in a prominent, clearly marked and protected place at the. ———-, for use by relocated units, 5.2

A

Housewatch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

T/F
Iroquois pipeline.
Duties of units may involve manually shutting down valves, and or patrolling the pipeline to locate the reported leak or fire.
5.3

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Iroquois pipeline
Isolation duties are typically carried out by manually, shutting down valves within the plant.
7.1

A

False
Isolation duties are typically carried out by remotely shutting down valves from the Iroquois gas control center.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Iroquois pipeline.
The initial actions of units responding to pipeline boxes are to do 2 things?
7.1.1

A

Set a perimeter
Eliminate sources of ignition 

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

T/F
Iroquois pipeline
Natural gas is lighter than air and will naturally disperse into the atmosphere. If the natural gas has ignited, consider?
7.1.1

A

Shutting down the gas supply

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

T/F
Iroquois pipeline
Due to extremely high pressure found in this pipeline system, consideration shall be given to allow escaping gas to naturally disperse into the atmosphere with the use of fog lines to assist in dispersal.
7.1.2

A

False
Without the use of fog lines

17
Q

Iroquois pipeline
The primary consideration is the?
7.2.1

A

Evacuation of the area involved

PS Initial actions is set up perimeter and eliminate ignition sources.

Consideration-Evacuation
Action- perimeter+ignition

18
Q

Iroquois pipeline.
Patrolling the pipeline to locate the leak will be performed by
—- or —— as designated by the IC.
7.2.3

A

Squad
SOC support ladder company

If rescue, squad or SOC support ladder company personnel are not available, the IC shall order available units to perform these duties.

19
Q

Iroquois pipeline.
Upon confirmation of the leak, transmit a ——— alarm for the street box nearest the leak location.
7.2.6 a

20
Q

Iroquois pipeline
Diesel power trains operate on these tracks and speed is limited in the area to? 7.3.1.

21
Q

Iroquois pipeline
The IC may position, flag persons at least ——- on each side of the incident.
7.3.1

A

At least 1000 feet

22
Q

Iroquois pipeline.
Flag Persons must be equipped with
Two things?
7.3.1

A

Handy talkies
Flashlight

23
Q

Iroquois pipeline.
Under no circumstances shall valves be operated without prior consultation with Iroquois /ConED personnel during drills. ——— closure of valves may be permitted after consultation with pipeline personnel. Under no circumstances—— closure of these valves be permitted during drills.
Note.
Page 5

A

Partial closure
Full closure

24
Q

Iroquois pipeline.
To use reserve gas to CLOSE valve, push —- the ——- (color) handle.
This should be the primary method to attempt to close this valve.
page 8

A

Push in
Red handle